HomeMy WebLinkAboutAgenda Report - April 7, 1993 (108)CITY OF LODE COUNCIL COMMUNICATIONr AGENDA TITLE: PUBLIC HEARING TO CONSIDER ADOPTION OF 1991 UNIFORM FIRE CODE MEETING DATE: April 7, 1993 PREPARED BY: Robert Gorbet. Fire Marshal RECOMMENDED ACTION: That the City Council conduct a public hearing to consider adopting the 1991 Uniform Fire Code and Amendments as preseited. FUNDING: None required. Robert L. G bet Fire Marshal RG/lh Attachments APPROVE THOMAS A. PETERSON City Manager CC0407.93 CC -1 ..._ r._..,:__._..___.._ ._..._._.�..._- ._.... ....,,, mss;. 11 MEMORANDUM. * _ r` ^ ?i , Fir D-.�-art-en 10: MAYOR AND rT^v =N FROM: F;oc %,'.ARSuAL DATE: Aprl'. 7, 1993 SUBJECT: UNIFORM FIRE CODE ADOPTION The Uniform Fire Codes are dedicated to fire life safety in all occupancies to protect property and human life. sections of the Uniform Fire code are already adonted by the State Fire Marshal and are enforceable as state law. Changes to the Codes are processed each year and published ever, three years in a form permitting ready adoption by local communities. Anyone may propose changes to the codes. These changes are carefully reviewed by code committees to become a part of the code. These meetings allow the free exchange of views leading to changes which are responsive to the concerns of the construction industry, design professionals and building officials. The State of California adopts the Uniform Codes by reference and requires cities and counties to adopt the same within six mtonths. This process insures uniformity in enforcement betweer_ jurisdictions. Included in this packet is the verbiage to adopt the Uniform Fire Code and any amendments or additions that have been made to conform to the requirements of the City Of Lodi. The proposed amendments have not been changed from the prior years adoptions with the exception of wording changes and deletions to conform with the 1991 Uniform Fire Code. e CITY O r LO D IFDate: OTICE OF PUBLIC HEARING ril 7, 1993 �. CARNEGIE FORUM 305 West Pine Street, Lodi 30 p.m. For information regarding this Public Hearing Please Contact: Jennifer M. Perrin City Clerk Telephone: 333.6702 NOTICE OF PUBLIC HEARING April 7, 1993 NOTICE IS HEREBY GIVEN that on Wednesday, at the hour of 7:30 p.m., or as soon thereafter as the matter may be heard, the City Council will conduct a public hearing to consider the following matter: a) Adoption of Uniform Fire Code All Interested persons are invited to present their views and comments on this matter. Written statements may be filed with the City Clerk at any time prior to the hearing scheduled herein, and oral statements may be made at said hearing. If you challenge the subject matter in court, you may be limited to raising only those issues you or someone else raised at the Public Hearing described in this notice or in written correspondence delivered to the City Clerk, 221 West Pine Street, at or prior to the Public bearing. By Order Of the Lodi City Council: (Jetni£� M. Perrin City Clerk Dated: March 3, 1993 Approved as to form: Bobby W. McNatt City Attorney 1 ORDINANCE NO. 1572 AN ORDINANCE ADOPTING THE "'UNI ORN. FIRE CODE. 1991 EDITION". AND THE APPENDIXES I -A, I -B. I -C, II -A, iI-B, II -C. II -D. I: -E, III -A, :II -C. ITT - D, IV -A, IV -3. V-A, VI -A, VI -B. Vi -D THERETO, WHICH CODE PROVIDES REGULATIONS GOVERNING THE CONDITION'S HAZARDOUS TO LIFE AND PROPERTY FROM FIRE OR EXPLOSION; REPEALING SECTIONS 15.20.010 THROUGH 15.20.480 INCLUSIVE OF THE CODE OF THE CITY OF LODI AND ALL OTHER ORDINANCES AND PARTS OF ORDINANCES IN CONFLICT THERE -4I Til . BE IT ORDAINED BY THE LODI CITY COUNCIL. Section 1. Section 15.20.010 through- :5.20.480 inclusive of the Code of the City o`_ Lodi is hereby repealed and is superseded and replaced by new sections _5.0.010 through- 15.20.450 inclusive as hereinafter set forth. Section 2_ There is hereby adopted new Sections 15.20.010 through 15.20.450 of the Code of the City of Lodi to read in fu:'_ as follows: 15.20.010 ADOPTION The provisions set forth in the "Uniform Fire Code, 1991 Edition" together with the appendixes --A, _-B, I -C, =--A, II -B, II -C, TI -D, 11-E, I_ --A, II'-C,IIID, IV -A, V -2t, VI -A, VI -B, VI -D thereto, are hereby adopted as the fire prevention code of the city. The fire prevention code of the city shall apply in all matters pertaining to storage, handling and use of hazardous substances, materials and devices; and to conn-- tions hazardo-as to life and property in the ase or occupancy of buildings or premises within the City. 15.20.020 AMENDED BY ADOPTION OF 1992 SII??L—_-MENT The "Uniform Fire Code, '991 Edition." is hereby amended by adopting the 199^ Supplement to the Uniform Codes relat:ag to the Uniform F --;=e Code, L': -for:.*. _-re Code Appendix: and the Fire _.de Standards, as promulgated by the .nternat_onal conference .,r Buildix:g Officials and the Western Fire Chiefs Association, and by this reference is made a Dart of this a_r.'_nance with the `orce and effect as 1 `_hough, set 0,ut`- 15.20.030 BUREAU OF FIRE PREVENTION The Rureac, of Fire Prevention stabl__`ed in the Fire Department c_ the City of _cd: and ...._ch shal'_ 1^e operated under the supervision of the ::h --e: c`_ the department. 7h a Bureau of Fire Prevention oha'_, enforce and is authori-zed to issue s chcr .ers cr notices 35 :nay -e necessary for `..tie � nl-orcemen.t of the Uniform Fire Core. ":at:ona_ Fare Codes and where necessar-, and appropriate, arty fire sections of the California Health and Safety Code, California renal code, and all other __tv, county or state fire or 'fife safety related laws or cotes net specifically covered in any -art of this code. 15.20.040 3URISD'C'_'ION DEFINED Whenever the woro ",Jurisdiction" is used `_he Un:form Fire Code it sha__ mean the City of odi_ 15.20.050 SECTIO' ^.101(1) ADDED RESPONSIBILITY FOR ENFORCEMENT Section 2.101(1) of the "Uniform Fire Code. '991 Edition_" adopted by Section 15.20.01-0 is added to read as follows: The apprehension, detention and oresezzt_on of those persons found t0 be in V�Qlat-on of the arson, explosive and fire insurance fraud sections of the Cal:=crnia Penal Code. 15.20.060 SECTION 2.103(b) ADDED FIRE PREVENTION BUREAU - ARSON INVESTIGATORS Section 2.103b of the "Uniform Fire Code. 1991 Edition" adopted by Section 15.20.013 added to read as follows: All sworn members assigned to the Fire Prevention Bureau are hereby assigned as Arson Investigators and as such shall enforce the provisions of "he Uniform Penal Code as it pertains to arson. - 15.20.070 SECTION 2.105 AMENDED AUTHORITY OF FIRE PERSONNEL TO EXERCISE POWERS OF POLICE OFFICER Section 2.105 of the "Uniform Fire Cod-. 1991 Edition_" adopted by Section 15.20.010 -s amended to _ead as follows: The Fire Chief an-? members zf - __re Prevention Bureau: shall b? peace 7rc_Cer as _:i Section 330.37 of 15.20.080 SECTION 2.303 AMENDED APPEALS Section 2.303 �`_ "he "Jni`_ _ire Code. 1991 Edition" adopted by Section 15.2C.010 amended to read as follows: Whenever the Fire Chief disapproves an application oz- refuses :refuses to grant a permit applied for, or when it :s c::_ -ea that the nrovis:ons of the fire prevention code do not app17 or that the true intent and meaning of the fire prevention code has been misconstrued or wrongly interpreted, the applicant may appeal from the decision of the Fire Chief to the City Council hia thirty nays from the datp t`. .e decision appealed. 15.20.090 SECTION 3.101 AMENDED VIOLATION Sectio, 3.1CI of the ":nifor^ Fire Coda, 1991 Ew_tion" adoptee by Section 15.20.010 is amended to read as follows: No person, whether as owner, lessee, sublessee or occupant, shall use, occupy or maintain any occupancy, :remises, or vehicle or cause or permit the same to be done. zontrary to or in violation of any of the provisions of this fire code or any lawful order issued by the Fire Chief or his authorized representatives under this chapter. Any person violating the provisions of this section is gu:'_ty of a misdemeanor for eac^ day such: violation continues. 15.20.100 SECTION 4.107(f) ADDED REVOCATION, SUSPENSION DENIAL Fire Section 4.10^(`) of ty "U e „r.:c orm __ a Ccde '1991 E4: _cn" :.co^Fee by Section 15.20.010 is added to read as follows: The Fire Chief further shall have the power to revoke, suspend, or deny the granting of any permit required pursuant to the provision of the Code for any of the following reasons: (a) When deemed necessary for the protection of life, limb, or proper`;, or (b) For the violation of any provi-ions of this Code; or (c) For changing the occupancy, equipment, materials, processes, or other conditions in s,-ich a ^anner as 3,:eatpr danger cf �_xn c 7_9ss Protection _'an ,•gas -,_a ____ at `^e tame _L i 15.20.110 SECTION 4.109 ADDED NEW "MATERIALS, PROCESSES OR OCCUPANCIES Section 4.10of the "Un;`_orm Firs Code, 1991 Edition" adopted by Section 15.20.010 ;s added to read as follows: The City Manager. Fire Chief and Fire Marshal shall act as a committee to determine and specify after giving affected persons an opportunity to be heard, any new materials, processes or eccunanc'-as. which shall require permits. in addition to those now en.—erated in the Code. The :ire Marshal shall post such l;st in a conspicuous place in his office and distribute copies thereof to interested persons. 15.20.120 SECTION 9.105 AMENDED DEFINITION Section 9.105 of the "Uniform Fire Code, 1991 'Edition" ado^ted by Section 15.20.010 is amended to read as follows: CENTRAL STAT.ON shall mean any U.L. listed office or station where person(s) monitor and/or receive emergency signals from alarm systems, and thereafter, relay messages from such signals by live voice to the City of Lodi Police/Fire Dispatch Center. 15.20.130 SECTION 10.204(a) AMENDED DIMENSIONS Section 10.1-04(a) of the "Uniform Fire Code, 1991 Edition" adopted by Section 15.20.030 is amended to read as follows: Fire apparatus access roads shall have an unobstructed width of not less than 24 feet and an unobstructed vertical clearance of not less than 13 feet 6 inches. road shall be not less than 24 feet. Vertical clearances or widths shall be increased when, in the opinion of the chief, vertical clearances or widths are not adequate to provide fire apparatus access. 15.20.140 SECTION 10.204(b) AMENDED SURFACE Section 10.204(b) of the "Uniform Fire Code, 1991 Edition" adopted by Section 15.20.0i.0 is amended to read as Lollows: Fire apparatus access roads snail be designed and maintained to support the imposed loads of `_ire apparatus and shall provide a permanent sur!ace of asphalt or concrete !.-stalled the full. width of all streets. cul-de-sacs and fire lanes . 4 15.20.150 'SECTION 10.301(a) AMENDED PREMISES . IDENTIFICATION Section 10.301(a) of the "Uniform Fire Code, 199: Edition" adopted by Section 15.20.010 is amended to read as follows: Approved numbers or addresses shall be placed on all new and existing buildings in such a position as to be plaint: visible and legible from the str-�t or road fronting the property. Said numbers shall contrast with their background. The approved minimum size dimensions of the numbers shall be as specified by Table 1 Where a building is set back from the street or road fronting the property and where addresses may not be clearly identifiable due to distance from the street or roadway, landscape and architectural appendages, or other obstructions, address posting shall be required both at the street driveway serving such building and on that building. ...................................................... TABLE 1 Distance to Building Address Size Measured From Back of Walk height 25 Feet 3 INCHES 26-40 Feet 5 INCHES 41-55 Feet 9 INCHES OVER 55 Feet 12 INCHES 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I 15.20.160 SECTION 10.301(c) ADDED PREMISES IDENTIFICATION - REAR Section 1.0.301(c) of the "Uniform Fire Code, 1991 Edition" adopted by Section 1.5.20.010 is added to read as follows: Any business which affords vehicular access to the rear through a driveway, alley way or parking lot, shall also display approved `dent.:. -i atio^ or address numbers or the .-ear of the build - ng for such business in a location approved by the Fire Chief. 5 15.20.170 SECTION 10.301(d) ADDED PREMISES IDENTIFICATION - MULTIPLE DWELLING UNITS Section 10.301(d) of the "Uniform Fire Code, 1991 Edition" adopted by Section 15.20.010 is added to read as follows: An approved diagram of the premises which clearly indicates all individual addresses of each unit in the complex shall be erected at the entrance driveways to every multiple dwelling complex having more than one building on "he premises or wher. required by the Fire Chief. In addition, the Fire Chief may require that individual buildings on the premises be identified in an approved manner. 15.20.180 SECTION 10.302 (a) ADDED HMMP BOX Section 10.302 (a) of the "Uniform Fire Code, 199; Edition" adopted by Section 15.20.010 is amended to read as follows: when a business which handles hazardous materials is required to complete a hazardous materials Management Plan, the Chief may require the installation of a secured box at the primary facility entrance containing a copy of the Hazardous Materials Management Plan. This box shall be waterproof and capable of holding the doc;iment in a rolled condition without folding. other characteristics of the box shall be approved by the Chief. Businesses which handle acutely hazardous material as defined in Section 25532 of the Health and Safety Code shall install a Hazardous Material Management Plan Box in accordance with this section. 15.20.190 SECTION 10.501 (d) ADDED FIRE EXTINGUISHERS Section 10.501 (d) of the "Uniform Fire Code, 1991 Edition" adopted by Section 15.20.010 is added to read as follows: All buildings and premises, except R3 occupancies, shall have installed and properly mounted in approved location a minimum of one fire extinguisher having a minimum rating of Type 2A:10BC or a pressurized water extinguisher having a minimum rating of Type 23, or of a quantity, type and location as determined by `_her Fire Chie`. Ai'• portable fire ex..a -::g::is::e_-s shall be serviced once a year. 15.20.200 SECTION 10.507(c)3 DELETED AUTOMATIC FIRE EXTINGUISHING SYSTEMS Section 1_0.507(c)3 of the "Uniform Fire Code, 1991 Ed4-:_on" adopted by Section 15.20.010 is deleted 15.20.210 SECTION 10.507(d) DELETED AUTOMATIC FIRE EXTINGUISHING SYSTEMS Section. 10.507(d) of the "Uniform Fire Code, 1991 Edition" adopted by Section 15.20.010 is deleted. 15.20.220 SECTION 10.507(1) ADDED AUTOMATIC FIRE EXTINGUISHING SYSTEMS Section 10.507(4-) of the "Uniform Fire Code. 1991 Edition" adopted by Section :5.20.010 is added to read as !ollows: In addition to the requirements specified in Sections 10.507(x) through 10.507(h), automatic sprinkler systems shall be ;nsta'_'_t:!d and maintained in an operable condition in the following s locations and in the following buildings hereafter constructed, remodeled or changed in occupancy regardless of the installation of area separation walls: (1) Every building hereafter constructed in which the total q floor area is 6,000 square feet or more. i (2) Every building hereafter constructed of three or more stories as defined in the Uaiform Building Code. ( ' (3) Every building hereafter remodeled when the cost i . accumulative cost of remodeling exceeds $ 100,000.00 and the total floor area is 6000 square feet or more. ` Remodeling is considered to occur when the first alteration of any wall, ceiling, floor or other structural part of the building commences, whether or not that alteration affects the external dimensions of £ the structure. The cost accumulation shall be calculated from the date of the first sprinkler ordinance. e The $ 100,000.00 valuation shall be based on Building � Valuation Data published by the International_ � Conference of Building Officials. ( 4 ) Every bun l di -0 _hinge :.^. classi`_icat:o. Ile `..ems`., L'_oor area _z 6.000 square { feet or more. Thd character -_` `_he occupancy of existing build--ngS may '..e-`ia:'c}�d _iz,abject to the approval of the Fire Chief. and the buiidIng r,.ay be occupied for the purposes in other groups without i • Section 11.20= through Sect -'.On 11.20'2 Of the "Uniform Fire Code, �99= edition" adopted by -ct_ __.^'0 _._- _meted. conforming tc the requirements o° this paragraph for those groups, provided the new or proposed use is less hazardous, ?,)ased on life and fire risk, than the existing use. ;5) This section shall not preclude or alter the .intent of the Un'_forr Building Code, Section 508. Fire resistive substitution. Buildings constructed for speculation purposes or buildings constructed without knowledge of occupancy c:assificatior shall have a sprinkler _ystem installed to meet the des-gn criteria of Ordinary hazard Group 2 as identified in the NFPA 1991 standards. Exceptions: Buildings divided into areas not greater than 6,000 square feet by area separations walls of not less than 2 -hour fire -resistive construction provided that: P a. Walls are constructed without openings and without penetrations for ducts. R b. No avenues exist that would allow `_re, heat or smoke spread between divided areas. C. The locatio: of the fire wall is clearly.marked and z identified --n the exterior o`_ the building in a manner approved by the Sire Chief. d. The `___e ;aal: is identif.ed 'n the interior of .he building in a r^anner approved by the Fire Chief. 1 e. An 8 1/2 -incl. by 11 -inch site plan is submitted r indicating the location of the fire wall in the s , building. The use of this exception may be denied or revoked by the . Fire Chief for due cause. a: For the purposes of applying this section, each portion of a building separated by one or more area senaration walls } shall not be considered a separated building. i 15.20.230 SECTION 11.201 - DELETED ARTICL? 11, DIVISION II SECTION 11.202 + Section 11.20= through Sect -'.On 11.20'2 Of the "Uniform Fire Code, �99= edition" adopted by -ct_ __.^'0 _._- _meted. 15.20. 240 SECTION 11.203 ;LME iDED OUTDOOR i IBES PROHIBITED Section. 11.203 of the "Uniform _ire Code, 1991 Edition" adopted by Section 15.20.010 is adc?Md to ?ad as follows: No person shall kindle or maintain any outdoor fire within the limits of the City of Lodi, except that this section shall not prohibit those fires that are approved by tile Fire Chief fc_ :he following purposes: a. The prevention of 3 Planarcl which cannot be abated by any other means. b. The instruction of public employees in the methods of fighting fire. C. The instruction of employees in methods of fighting fire, when such fire is set, pursuant to permit, on property used `_or `.^_dastrial 2urposes. d. The setting of l:aClf _"es necessary to save 'life or valuable property pursuant to Section 4426 of the Public Resource Code. e. The abatement of fare hazards pursuant to Section 13055 of the health and Safety Code. f. Disease or pest prevention, where there is an irmed ate need for and no reasonable alternative to burring. Nothing in this section shall be construed as prohibiting open outdoor fires used only for cooking food for human consumption where such use is accomplished in an approved fireplace or barbecue pit, or for recreational purposes areas approved by the =ire Chief, provided that the combustible material is clear dry wood or charcoal. 15.20.250 SECTION 11.206 ADDED CONSTRUCTION SITES Section 206 of the "Uniform Fire Coder, 1991 Edition" adopted by Section 15.20.010 is added to read as follows: No fires shall be permitted to bu=n on any construction site for any purpose. This section is not to ?rohibit the use of devices or tools producing- a flame when used in an approved manner and necessary for the construction of the building. I5.2?.26C SECTION 11.3C= DELETED PARADE FLOATS Section '_1.304 of the "Uniform 7 -.A -e, 1991 3_?ition" adopted by Section _5.20-%Cj is del -r -ted. v 7 r I 0- 15.20.270 15.20.270 SECTIOIt 11.305 ADDED ALLEYS TO BE REPT CLEAN Section 11.305 of the "Uniform Fire Code. 1991 Edition" adopted by Section ::.20.17-0 is added to re -ad as follows: No person owning or occupying or having- the possiss'_o:: o- -control of any property bordering on any public alley in t-1 City of :.odi s%&11 fail. refuse or neglect to keep that portion of such al:vy bFtween the centerline thereof and the property line of such property free from accumulations of waste paper, hay. nr3ss, :straw weeds, litter or comii:ist b'_e or flammable waste material, waste Fetroleum.product.s o: rubbish of any kind. 15.20.280 SECTION 11.306 ADDED HOUSEKEEPING AND FIRE NUISANCE Section 11.306 of the "Uniform Fire Code, 1991 Edition" adopted by Section 15.20.010 is added to read as follows: hI1 buildings and premises shall be maintained in good repair and in a clean and orderly marine_, free from any condition that presents a fire hazard or a condition which would contribute to the rapid spread of `_ire. 15.20.290 SECTION 1-1.307 ADDED ELECTRICAL DISCONNECT Section 11.307 0£ the "Uniform Fire Code, 1991 Edition" adopted by Section 15.20.010 is added to read as follows: All buildings providing electrical service through more than one (1) service meter or through multiple service connections, shall have each main electrical disconnect identified in a manner approved by the chief indicating areas or units served. 15.20.300 SECTION 11.308 ADDED GAS DISCONNECT Section 11.308 of the "Uniform Fire Code, 1991 Edition" adopted by Section 15.20.01C is added to read as follows: All buildings providing natural gas service through more that one (1) service meter or through multiple service connections, shall have individual gas shut -offs identified in a manner approved by the chief indicating areas or units served. 15.20.310 SECTION 14.111 ADDED REGULATED SYSTFAS s Section 14..1.11- of the ".:n if�r^t ire 17ca de, 1993. Edition" adopted �• by Section 15.20.010 is added to read as follows: Appendix III -C of the "Uniform Pi -re Code. 1991 Edition" shall apply to all ,ire Sprinkler Systems, Standpipes and ^ Combination Systems installed, regardless if the system was installed as a requirement of any code or not. The date of installation or the date o` an approved inspection conforming to the requirements of Appendix !_TI -C shall be used when applying interval periods. 15.20.320 SECTION 25.115 AMENDED LIGHTED CAUDLES AND OTHER OPEN FLAME DEVICES Section_ 25.115 of the "Uniform Fire Code, :35: =Edition" adopted by Section 15.20.010 is amended to read as follows: No person shall place or maintain, or permit to be placed or maintained, any lighted candle on any tree or shrub, or use or maintain any candle or other open flame device in any building or place in such a manner as to create a hazard to life or property as determined by the Fire Chief. 15.20.330 SECTION 25.116 - DELETED CANDLES AND OTHER OPEN LAME DEVICES Section 25.116 of tl- "Uniform Fire Code, 1991 Edition" adopted by Section 15.20.010 is deleted. 15.20.340 SECTION 77.107(x) LI?TITS EXPLOSIVE AND BLASTING AGENTS The limits referred to in Section 77.107(a) of the "Uniform Fire Code. 1991 Edition" adopted by Section 15.20.010 in which the storage of explosives and blasting agent, is prohibited is the entire city except in areas zoned M-2 as such zone is defined in the zoning regulations of the City. 15.20.350 SECTION 78.103(a) AMENDED MANUFACTURING OF FIREWORKS Section. 78.103(a) of the "Uniform Fir- C -ad.-. 7 -SS! Edition" adopted by Section 15.20.010 is amended to read as follows: The manufacture o= f - -awort?_ w-* t4 _r -' 'Q r �.'�tS of tj, r_ty r 15.20.360 SECTIOIi 79.111 AMENDED OPERATING HEATIIIG, LIGHTING, COOKING APPLIANCES Section 79.11_ of the "Unifo = Fire Code, 1991 Edition" adoated by Section 15.20.010 is amended to read as follows: Heating, lighting or cooking appliances which utilize Class I liquids shay_ not be operated withi:+ any L-u:lding or structure. 15.20.370 SECTION 79.13.6(9) ADDED STORAGE OF TANKS Section 79.116(g) of the "Uniform Fire Code, 1991 Edition" adopted by Section 15.20.010 is added to read as follows: Underground tanks that have been remov?d from the ground and aboveground tanks that are no longer in service shall be clear of flammable vapors ,-ts '_^_: an approved testing lab. The Fire Chief may limit the number of t_ammable liquid tanks that are stored on any property. The storage of tanks shall be as approved by the ?ire Chief. 15.20.380 SECTION 79.501 LIMITS STATIONARY TANK STORAGE, ABOVEGROUND OUTSIDE OF BUILDINGS The limits referred to in Section 79.501 of the "Uniform Fire Code, 1991 Edition" adopted by Section 15.20.0:0 is which the storage of Class I and Class II liquids in aboveground tanks outside of buildings is prohibited in the entire city except areas zoned C -M, -1 and u-_ as such zones are defined in the Zoning reaulaticns of the city. 15.20.390 SECTION 79.90-1a AMENDED SPECIAL ENCLOSURES Section 79-902c of -,he "uniforn Pi -re Code. 1791 Edition" adonteG= by Section 15.20.010 is amended to _eiri 3s follows: Special Enclosures. When installation of tanks in accordance with DiJis--on V_ __=:Rp_actica-1 or because of property or Jll_ilii-irdta`_ions. Lor Class _ _ or _, _„ III -d liquids ,,-.ay be _:�:--__e'. _-. �::dines if e.^.•::_used z.s follows: EncloSu--it -^?" _ '.iCuii1 i=713. 3?d veno+" tight Wittout jbackfi? 12 1 2. sides, top and bottom of the enclosu_- shall. he of reinforced concrete -at _east 6 inches thick, wi`.h onenirgs for insaection through the top e ' . . 3. Tank connections shall be so piped o71- that neither vapors nor liquid can escape 'into -nC-_cs!E-a space. 4. Means shall_ ap ?rovided wht-.:-by portable equipment may be employed to discharge to the outside any vapors which might accumu? .ite shot:? c4 leakage occur. 5. Tanks containing Class 1, .1 or !IT -A liquids providing storage within a special enclosure in a building or in an outside above5round special enclosure shall not exceed 1100 gallons individually or 1100 gallons aggregate per parcel. The storage of Class I II or III -n flammable or combustible liquids within_ a special enclest:=e a buildirc or in an outside aboveground special erclosu_! i5 except areas zoned C -IM, M-1 and M-21 as such zones are defined in the zoning regulations. Class I or Class _I liquids may be dispenses? into the f=uel tank of a motor vehicle from an outdoor aboveground special enclosure conforming to this section. outside aboveground sp-sial enclosures shall have tanks enclosed by reinforced concrete at least _ inches thick and shall be constructed per Underwriters Laboratories Specifications U.L. 2085. Fill opening shall be equipped with a closure designed so that it may be locked. outside aboveground special enclosures shall be at least 10 feet from any building or combustible storage and so located as such additional distance shall' be provided as will ensure that any vehicle, equipment or container being filled directly from such tank shall be not less than =0 feet from any s`_ructuYe or other combustible. Outside aboveground special enclosures shall be kept at least 5 feet from property line and public gays. ^laminable and combustible 1 iaui0 - sL:31: not transferred from aboveground special enclosures by gravity discharge. electrical controls shall r' t '.l'_ _-:ui ements of Section .. n. 903"e G the- n�:ll. Dispensing di!vices s^al ' ­)nfo_m.. to Section 79-4013c of the r.. Vents shah me—:et all re-quirements, '_ c of able "Uniform F -4 -re Code, 199: �ditioR��. Portabl'A fire extinguishe.-s with a m imLim. classification of 2A, 20B:C sial: ^e provided and so 'located that it w_'__ be not Tore than 75 feet from any nt1m?. A conspicuous sign prohibiting smofir-7, an;'_ requiring the motor to be shut off during fueling operations shall be Hosted. Aboveground 5nec a_ .nclosures shall display a rlammable placard on bothh sides of the special enclosure on opposite corners, the tape and material stored shall also be displayed directly below the flammable placard. The grade of the land shall be such that a fuel spill will not drain to a storm drain, buildir_g or ot''er exposure. Protection against physical damage shall be povided as required by "he ; -ire chl of . 15.20.400 Section 79.903(x) AMENDED ABOVEGROUND TANKS Section 79.903(a) of the "Uniform Fire Code. 195= adovted by Section :5.20.01-0 is amended t:. •_eai1 .zs Class _ and Class __ liquids shall not be dispensed into the fuel tank of a motor vehicle from a>ovenraund tanks. 1. As provided for in Section 79.902(c) 2. Dispensing of Class I1 liquids into the fuel tanks of motor vehicles from an approved aboveground fuel_ dispensing system for private, non -retail use when in conformance with Section 79.912 15.20.410 Section 79.922 ADDED DISPENSING iNTD FUEL TANKS OF MOTOR VEHICLES FROM ABOVEGROUND TANr:S Section 79.912 of the "Uniform ?ire Cade, 1991 12dition" adopted by Section 15.20.010 --s added to read as follows: SCOPE This section shall appy to -nex� and =.:sting locations. TANK CONSTRUCTION zrovearound `ank_G used tc_r (ispens.i.na of C_3.E+s the } -sic• f r a .rteh - -e i ilei _1!'Li2tZ5 Into _a._..� C � .O_ _ _C:�'= __ 7rOh �J ,. �.. except in areas zoned :.r__. jtf is •sr'N1MIftitP.2�.�['.'✓.M.waw.eJr+�s :.. ... _....__ .. .. ..:.. .•.�...rd ��_..�... ... .... .... r ^antis shat= be built to meet :;nderwrita:7s Laborat,:�_i>s Inc., Ste-Aard fob Steel Above round I, t.s for vlarmab'e -g ----- -- and Co?T'.l"'U_ iblt__u^L12�5, U.L. i'e? Tanks shall' hie securely supported by concrete. masonry or protected steel. 'Tanks supports steal: rest on foundat:o.^.s of concr?tel ^ank fo ndat or -s b.n r-nhe possibi'=ty of ,nevend=signed to ta of "he e tank.kr_. t Steel supports for tanks Shall have a fare resistance- esistancerating ratingof not less than `_c:o horns, a-cept that sot'•' ;•,', steel saddles need not be protected :f 'less than __ inches at their 'Lowest Point. s Design of supports shall be in accordance with Section i 79.505(d) c rite teniform ^ire Code, I59I Edit: o n Normal venting and emergency venting shall -eea_ :1 I requirements of Section 79.509 of the "Uniform ='ire e Code, 1-.39' ^dz`_:on". 4 Ali cenneetior_s, `ittinq-z o= other- appurtenances shall 7_pi:;; be installed in accordance with _vision 'I'_, --pi-g.. Valves and Fittings." ) Tanks containing Class Zi liquids steall not exceed J. 000 ;at _o_^_s and s' a:: be limited tc one tan=_ ger parcel. ¢ Y. CONTAINMENT WALL A containment wall of concrete or masonry shall be constructed regardless of tank construction and shall be E designed to contain 110 percent of the tank capacity. i The containment wall shall have no side closer than IF feet to any property line or building. i The minimum distance between tanks and the interior , t containment wails shal'_ be not less than 3 feet and not more than 5 feet. Containment wails s.ia:: not be Less than feet --- --:.fight and not more than 5 feet _r height. Provision she"_ be n:ade for removing Vater f: om rile containment area -in acco;car_ce wtl: Secticn 79.5C7. =ai water dra inage should 'tee c:Fsigned to -:x_ - +elow `Icor i - �=-�i:::i J.. _.� � rlOt .:? ._ _ ll •. .. _ _ .. .+� a:. -G'.: _S:l .:VRt^- :�:�.^.t {.. The runt �_>� __, - , i e - ment a-; a -'='' - '� �_ -- - -- coral st_bI_ _ materia' , empty or f'.:: - i:_^s c_ !.gar- ___. -- 3 p I ELECTP.ICAT �'i �Ctri-C31 Controls shall meet all - . c -Tui -ement s of y Section 7^1 t � .r.tn i'_orTn- _ __? Coi _x9 1 _?la=i?r DISPENSTIM SYSTEMS Dispensing systFMs shall. not be by gravity feed. anO be designed t_., :_..._t the quantity dispensed to 150 gallons each activation Of the dispensing system J installed a`_ } top of tt:' T_'•ispensing .um -Ti's shai' ? he tanks. A .normally closed sole-noid valve is to be installed on the outlet of he c':_spensia _7 pump. 711s Valve --s to be electrically wi_ed so that it will open when the pump is operating. Dispersing devices sl�a'_'_ conform to Section 79 -90 -le of the "Uniform erode, 139= ;dition". Each pump shall have installed on l`:e discharges an ,. aDDL-C1Ved IJaL-r_'Ct.?r�:On iTeVi Ce whichr___ '1_OV1C�.2 ai indication if the piping and disp_ns-_= essentially liqjid tight. Protection against physical damage shall the rovide-i as reouired by the fir-, Chief. The systemt--ste-d SAFETY RULES Portable firs extinguishers With a ^t1_n_=^Sum classn=ratio'_: of 2A-20SC shall be provided and so located: "-:at it will be not more thaw 75 feet from any pump. A conspicuous sign prohibiting simoki ng. and=ecuiri^_g the motor to be shut off during fueli::g operations shall be posted. The grade of the lard shall be such that a `uel spill will not drain to a storm drain, exposure. The system sites shall lbe provided T•7_t'_: _. 2_ -ea' -arm trans^lit`ing aev ce. Such a dev:c^ 1._ t._IeDhona :lot relu='_-4-ng ? ;.r._n tO n-»r3t2. 15.20.420 SECTION 79.1401(b) ADDED FLAMMABLE LIQUID BULK Sectio^. 7i.1=0.b Cc `t:. •• •n: ^.T _ __ _ I — :_c't -dit-: adODted �,_ -ad :7`'1'!-.. by Section _s New 'jui ?1 a1: `.._ c`,_ — ^'--. .,_ -. 71? :.l-�b!- a- e .Z.....:able _L_ s_t4u14� are 5 <F Drohibi}ed in the enti. e cit-.- except in the area coned `a-' as such =one is defined -._ the :cn_. g regulations of the Cit- of '_odi. 15.20.430 SECTION 82.104(b) LIMITS LIQUID PETROLEU14 GAS STORAGE LIMITS The limits referrer? to in Section 82.104b of "i- ".7ni`or Fire Code. 1991 Edition" adopted 'air Section 1-.20.01C -:. which `_tie storage o`_ `liquified petroleum gas is rrohibited -s the entre c'_ty except areas =oned v,-2 as such =one _s defined in.the =oninc regti?ations of the Ci"_v of Lodi 15.20.440 APPENDIX I -A. AMENDED EFFECTIVE DATE SECTION 1(b) Appendix: I -A, Section 1b of the "Uniform Fire Code, =991 Edition" adopted by Section 15.20.010 is amended to read as follows: Within 90 days from the date of written notification to the building owner and occupant requiring compliance of th_c appendix plan- for shall be submi`_`_ed ani approved, and within 12 months thereafter the work zha! l be t completed or the building shall be vacated unti. :rade to } conform. F 15.20.450 APPENDIX I -A, ADDED EXIT ILLUMINATION SECTION 2(f) S Appendix I -A, Section 2(`-) of the "Lnifx-^t _ _re rode. 1199' # Edition" adopted by section- .2C.010 is added to read as follows: Exit it 1uri^..atiC-2 shall be provided as required 'by the Building Code. i Section 3. All ordinances and parts of ordinances in conflict herewith are repealed insofar as such conflict may f exist. . ! Section This ordinance shall be published one tir..e in _4_._ the "Lodi News Sentinel," a newspaper of genera'_ circulation orinted and published in the City of Lodi and shall be in Force and tate ef`-ect thirty days aft:- passage. App ovei� at =_ day of , 1993 Maycr 1 Attest: Jennifer ?e,`rin City Cler'j State o° Cal iFornia County of San „oaquin. ss. Jennifer Perrin, City Clerk of the City of Lodi, do hereby certify that Ordinance No. 1572 was _ :`roduc­'- reg,-,Iar e`_ the City Co.. -c-;_'_ c'` '... `; �` •-': he?d Ag,kie 7. 1993 and was therea`_ter-nesse: , and ordered to print at a regular meetinq of said .:ounci'_ held by the `_ollowi-.c vc`:. s, Ayes: Council Members C - Noes: Council ;_embers - Absent: Council Members - Abstain: Council Members - tie^e I Further certify that Ordinance No. 1572was approved and signed by the Mayer an the date o_` its : a33agc t--3 has been published pursuant to law. -- - -- -- i Approved as to _`orr. j4 i Robert McNatt City Attorney • x. is 1 . r CITY OF LODI t 221 WEST PINE STREET LODI, CALIFORNIA 95240 ADVERTISING INSTRUCTIONS SUBJECT: NOTICE OF PUBLIC HEARING - ADOPTION OF UNIFORM FIRE CODE PUBLISH DATES: SATURDAY, MARCH 6, 1993 TEAR SHEETS WANTED: THREE AFFIDAVIT AND BILL TO: JENNIFER M.PERRIN, CITY CLERK DATED: MARCH 3. 1993 ORDERED BY : �I'/c (E l jC PE COLINI DEPUTY CITY CLERK ADVINS/TXTA.02J ----'TICE I ICE O PUBLIC HEARING CITY O � LODI � Date: April 7, 1993 CARNFGIF FORUM Time: 7:3o p.m. 305 West Pine Street. Lodi For information regarding this Public Hearing Please Contact: Jennifer M. Perrin City Clerk Telephone: 333.6702 NOTICE OF PUBLIC HEARING April 7, 1993 NOTICE IS HEREBY GIVEN that on Wednesday, at the hour of 7:30 p.m., or as soon thereafter as the matter may be heard, the City Council will conduct a public hearing to consider the following matter: a) Adoption of Uniform Fire Code All interested persons are invited to present their views and comments on this matter. Written statements may be filed with the City Clerk at any time prior to the hearing scheduled herein, and oral statements may be made at said hearing. If you challenge the subject matter in court, you may be limited to raising only those issues you or someone else raised at the Public Hearing described in this notice or in written correspondence delivered to the City Clerk, 221 West Pine Street, at or prior to the Public Hearing. By Order Of the Lodi City Council: iti t��'r � j �_Le,o•r�- ennifth M. Perrin City Clerk Dated: March 3, 1993 Approved ds to form: Bobby W. McNatt City Attorney