Loading...
HomeMy WebLinkAboutAgenda Report - March 6, 2002 E-04CITY OF LODI COUNCIL COMMUNICATION AGENDA TITLE: Approve specifications and authorize advertisement for bids for power utility duct and fittings (EUD) MEETING DATE: March 6, 2002 PREPARED BY: Electric Utility Director RECOMMENDED ACTION: That the City Council approve the specifications and authorize advertisement for bids for power utility duct and fittings listed below. BACKGROUND INFORMATION: The Engineering Division of the Electric Utility Department is preparing or has prepared work orders for installation of electrical service in several new residential subdivisions. Items and quantities expected to be required for those work orders are as follows: 2" Power & Communications (P&C) Duct DB120 Conduit 50,400 feet 2" PVC Schedule 40 Longline Coupling 600 each 2" PVC Schedule 40 22.5 -degree Elbow, 36" Radius 200 each 2" P&C DB120 90 -degree Elbow, 36" Radius 575 each 2" P&C DB120 45 -degree Elbow, 36" Radius 70 each 3" P&C Duct DB120 Conduit 20,000 feet 3" PVC Schedule 40 Longline Coupling 500 each 3" PVC Schedule 40 22.5 -degree Elbow, 18" Radius 60 each 3" P&C DB120 90 -degree Elbow, 36" Radius 300 each 3" P&C DB120 45 -degree Elbow, 36" Radius 25 each 4" P&G Duct DB120 Conduit 1,140 feet 6" P&C Duct DB120 Conduit 3,640 feet Clear PVC Cement 120 qts Some of the subdivisions planned for service installation (carried over from 2001) are Century Meadows #1 Unit 2, Century Meadows #4 Unit 2, Tienda Place Units A & B, and the Beck/Perlegos subdivision in Grid 58. FUNDING: Electric Utility Department's Operating Fund, Page D-37 Estimated Cost: $56,000 BID OPENING: March 20, 2002 A /� affit.— Alan N. Vallow, Electric Utility Director Prepared by Joel Harris, Purchasing Officer c Manager, EUD Engineering and Operations APPROVED: i G" ccs 2002.doc Im"Pixon Flynn -- City Manager 02/28/02 SECTION 4, PAGE 1 POWER UTILITY DUCT & FITTINGS EQUIPMENT SPECIFICATIONS SECTION I - POWER UTILITY DUCT General: This specification is for power and communication duct for use in the City of Lodi's 12.0- kv underground distribution system. Specific Specifications: Polyvinyl chloride (PVC), direct -buried duct, DB -120. Lengths, overall, including integral coupling: 20 ft., +1 -0 inch. Standards: The duct shall meet the requirements of the latest editions of applicable NEMA TC -6, NEMA TC -8 and ASTM F-512. Shipping: As required to ensure product integrity and quality upon delivery. Markings: All required markings shall be legible and so applied as to remain legible under normal handling and installation practices. Duct shall be marked with the following: 1. Manufacturer's name or trademark 2. Nominal size 3. Material: (PVC) 4. NEMA (TC -8) and ASTM F-512 5. Type: (DB -120) 6. Any additional marking deemed necessary by the manufacturer. SECTION II - FITTINGS The following manufacturers and their respective part numbers have been approved and are acceptable for this bid: Item Description I Carlon I PWPi a I Cantex 2" Sweep 900, DB -120 36" Radius PH9FJ 8190360200 5125869 2" Elbow 450,1313-120 36" Radius PH7FJ 8145360200 5125879 2" Elbow 22.50, PVC Sched 40 36" Rad. BE UA5FJB 7522360200 5233851 2" Coupling, PVC Sched 40 Lon line E941J 60020200 6202000 3" Sweep 900, DB -120 36" Radius PH9FL 8190360300 5125872 3" Elbow 450,DB-120 36" Radius PH7FL 8145360300 5125772 3" Elbow 22.51, PVC Sched 40 18" Rad BE UA5CLB 7522180300 5233845 3" Coupling, PVC Sched 40 Lon line E941L 60020300 6202005 4-1