Loading...
HomeMy WebLinkAboutAgenda Report - July 19, 2000 E-1620SS® DRESS FOR LESS June 20, 2000 Mr. Alan Vallow City of Lodi Electric Utilities Director 1331 South Ham Lane Lodi, CA 95242 Re.: ROSS DRESS FOR LESS 340 West Kettleman Lane Lodi, CA Dear Alan: Property Development Ross Dress For Less is requesting $15,869.75 from the city of Lodi's Public Benefits Program grant fund. This will be utilized to supply seven high efficiency air conditioning units as well as energy efficient lamps, ballasts and exit signs. Ross will use the above listed equipment in its upgrade of the Lucky's grocery store that formerly occupied this space. We install such equipment to minimize the consumption of energy resources and to ensure optimal comfort for our customers and employees. The attached equipment information and costs are provided at the request of Mr. Rob Lechner, Manager of Customer Programs. Ross Stores, Inc. operates a national chain of off-price retail stores offering first quality, in -season, branded apparel and apparel -related merchandise for the entire family., The average store features about 29,000 gross square feet in a self-service, easy -to -shop format that is conveniently located in neighborhood shopping centers. Ross looks forward to beginning its operations in the city of Lodi and appreciates your consideration of this request. If you have any questions, please do not hesitate to contact me at 510.505.4839. M' Constructio anager cc: R. Lechner, City of Lodi J. Haskins File attachments Real Estate • Property Management • Construction • Store Design • Facilities ROSS STORES, INC. • 8333 Central Ave., Newark, California 94560-3433 • (510) 505-4400 Phone • (510) 505-4174 Fax 1 Lennox National Accounts Quo ROSS D.F.L. Plan ID Quantity Description AC -1 AC -2 1 LGA088H Package Gas Unit (7.5 Tons) 1 Unit Orientation: Downflow 1 460 Volt/3 Ph (Factory) 1 2 Hp Std. Efficiency Blower Motor (Factory) 1 Drive Kit 1 (Factory) 1 125KBTU Alum. Steel (Dual Stage) (Factory) 1 Global Economizer (Factory) 1 Downflow Gravity Exhaust (Factory) 1 Novar ETM -2051 Kit (Factory) 1 Rm. Sensor for Novar 97H53 1 14 inch Downflow Curb 17L53 1 Return Air Smoke Detector (Factory) 1 Supply Air Smoke Detector (Factory) 1 80 Amp Disconnect (Factory) 1 GFCI (Field Wired) (Fry) 1 Burglar Bars 3/4" L 088-100S 65NO2 ReCeiWo MAY O4 u -v March 28, 2000 LODI, CA Material LGA088H-PKG 1 LGA036H Package Gas Unit (3 Tons) LGA036H-PKG 1 Unit Orientation: Downflow 1 460 Volt/3 Ph (Factory) 1 .75 Hp Direct Drive Blower Motor (Factory) 1 78KBTU Alum. Steel (Single Stage) (Factory) 1 Manual Outdoor Air Dampers (Factory) 1 Novar ETM -2051 Kit (Factory) 1 Rm. Sensor for Novar 97H53 1 14 inch Downflow Curb 45J19 1 80 Amp Disconnect (Factory) 1 GFCI (Field Wired) (Factory) 1 Burglar Bars 3/4" L 036-072 44N17 AC -3 1 LGA 156H Package Gas Unit (13 Tons) LGA156H-PKG 1 Unit Orientation: Downflow We are pleased to provide the attached project quotation. If yoa have any questions or need adddional information, please feel free to call our office. Project Nbr: U603Q260K0-01 Prepared By: adf00 Page 1 of 3 Lennox National Accounts Quotation March 28, 2000 ROSS D.F.I. LODI, CA Plan ID Quantity Description Material 1 460 Volt/3 Ph (Factory) 1 2 Hp Std. Efficiency Blower Motor (Factory) 1 Drive Kit A (Factory) I 169KBTU Alum. Steel (Single Stage) (Factory) 1 Global Economizer (Factory) 1 Downflow Gravity Exhaust (Factory) 1 Novar ETM -2051 Kit (Factory) 1 Rm. Sensor for Novar 971153 1 14 inch Downflow Curb 161(87 1 Return Air Smoke Detector (Factory) 1 Supply Air Smoke Detector (Factory) 1 Circuit Breaker 40 Mips (Factory) 1 GFCI (Field Wired) (Factory) 1 Burglar Bars 3/4" L 156-240 44N20 AC -4,6 2 LGA120H Package Gas Unit (10 Tons) LGA120H-PKG 2 Unit Orientation: Downflow 2 460 Volt/3 Ph (Factory) 2 3 Hp Std. Efficiency Blower Motor (Factory) 2 Drive Kit 1 (Factory) 2 130KBTU Alum. Steel (Dual Stage) (Factory) 2 Global Economizer (Factory) 2 Downflow Gravity Exhaust (Factory) 2 Novar ETM -2051 Kit (Factory) 2 Rm. Sensor for Novar 971153 2 14 inch Downflow Curb 53K50 2 Return Air Smoke Detector (Factory) 2 Supply Air Smoke Detector (Factory) 2 80 Amp Disconnect (Factory) 2 GFCI (Field Wired) (Factory) 2 Burglar Bars 3/4" L 090-150 44N19 AC -5,7 2 LGA180H Package Gas Unit (15 Tons) LGA180H-PKG 2 Unit Orientation: Downflow 2 460 Volt/3 Ph (Factory) 2 3 Hp Std. Efficiency Blower Motor (Factory) 2 Drive Kit A (Factory) 2 260KBTU Alum. Steel (Dual Stage) (Factory) 2 Global Economizer (Factory) 2 Downflow Gravity Exhaust (Factory) We are pleased to provide the attached project quotation. If you have any questions or need additional information, please feel free to call our office Project Nbr: U603Q260K0-01 Prepared By: sdfO0 Page 2 of 3 Lennox National Accounts Quotation March 28, 2000 ROSS D.F.L. LODI, CA Plan ID Quantity Description Material 2 Novar ETM -2051 Kit (Factory) 2 Rm. Sensor for Novar 97H53 2 14 inch Downflow Curb 16K87 2 Return Air Smoke Detector (Factory) 2 Supply Air Smoke Detector (Factory) 2 Circuit Breaker 45 Amps (Factory) 2 GFCI (Field Wired) (Factory) 2 Burglar Bars 3/4" L 156-240 44N20 Notes: • This quotation is contingent upon the successful contractor meeting all of Lennox Industries standard terms and conditions including satisfactory credit arrangements. • Prices contained in this quotation are firm for a period of 30 days from bid date and are subject to change after that period without notice. • All past due accounts may be subject to a service charge of one percent (1%) per month. • MI sales of special order and configured products are final. Returns will not be allowed. • All accessories are field installed unless specifically indicated. • Order cancellation within 15 days of scheduled ship date will result in a restock charge on all units containing factory installed options. • CONTRACTOR TO VERIFY VOLTAGE. • FREIGHT PREPAID TO FIRST DESTINATION. • EQUIPMENT OPERATIONAL CHECK (EOC) INCLUDED. • ANY ITEMS NOT SPECIFICALY LISTED, ARE NOT INCLUDED. I JOB TOTAL SELL PRICE (Tax Not Included): S47,951.001 We are pleased to provide the attadied project quotation. If you have any questions or need additional inforntation, please feel free to call our office. Project Nbr. U603Q260K0-01 Prepared By: sdf00 Page 3 of 3 JUN -06-2000 11:27 P.01 AMERICAN WHOLESALE LIGHTING it Job Nameh Ross /Lodi, Ca. Bill to: Ross Dress For Less Q Manufacturer Item Number 343 Magnatek B232I277RH 292 Magnatek B432I277RH 7 Surelites CX -7170-G 1917 Osram F032/735 (21823) Sales tax is not included Date: 6/5/00 Ship To: Ross Dress For Less West Lane Shopping Center 340 W. Kettleman Lane Lodi, Ca., 95240 Description Unit once Extension $16.00 $5,488.00 1 or 2 -Lamp electronic T8 ballast 277V 4 -Lamp electronic T8 ballast 277V $19.45 $5,679.40 LED exit sign $116.35 $814.45 $1.85 $3,546.45 4' Fluorescent lamp 41400 Christy Street • Fremont, CA 94538 (510) 252-1088 (510) 252-1090 FAX (800) 253-6736 Total $15,528.30 Lennox Industries, Inc. Product Submittal March 28, 2000 ROSS D.F.L. LODI, CA Project Information: U603Q260K0-01 ROSS D.F.L. LODI, CA Prepared By: sdf00 We are pleased to provide the attached project submittal. If you have any questions or need additional information, please feel free to call our office. Lennox Industries, Inc. - Product Submittal ROSS D.F.L. Table of Contents March 28, 2000 LODI, CA Plan ID Quantity Description Page AC -1 1 LGA088H Package Gas Unit (7.5 Tons) 3 AC -2 I LGA036H Package Gas Unit (3 Tons) 6 AC -3 I LGA156H Package Gas Unit (13 Tons) 8 AC -4,6 2 LGA120H Package Gas Unit (10 Tons) 11 AC -5,7 2 LGAI80H Package Gas Unit (15 Tons) 14 Submittal Nbr: U603Q260K0-01 Lennox Industries, Inc. - Product Submittal ROSS D.F.L. Unit ID: AC -1 SPECIFICATIONS AND RATINGS Packaged Cooling & Gas Heating March 28, 2000 LODI, CA Model number LGA088H Package Gas Unit (7.5 Tons) Sound rating number (db) 86.0 HEATING Heat source Natural Gas Gas supply pressure 7.0 (in. W.C.) Gas supply connection 0.75 (in.) Heating capacity input (low stage) 83,000 (Btuh) Heating capacity output (low stage) 66,000 (Btuh) Heating capacity input (high stage) 125,000 (Btuh) Heating capacity output (high stage) 100,000 (Btuh) AGA -CGA thermal efficiency 80.0 COOLING ARI gross cooling capacity 90,000 (Btuh) ARI net cooling 85,000 (Btuh) ARI total unit watts 8,330 ARI EER (Btuh/Watts) 10.2 Entering evaporator dry bulb temperature 80.0 (deg F) Entering evaporator wet bulb temperature 67.0 (deg F) Outside air dry bulb temperature 95.0 (deg F) Gross cooling capacity 85,650 (Btuh) Sensible cooling capacity 58,670 (Btuh) Leaving evaporator dry bulb temperature 55.9 (deg F) Condensate drain size 1.00 fpt (in.) Refrigerant type HCFC -22 BLOWER PERFORMANCE Blower air volume 2,250 (CFM) External static pressure 0.60 (in. W.C.) Required blower motor including wet coil 1.04 (hp) Nominal blower motor 2.0 (hp) Required RPM 938 RPM range 845 - 1130 Air filter quantity 4 Air filter length x width 18 x 20 (in.) Air filter thickness 2 (in.) ELECTRICAL Power supply 460 V 3 Phase Unit operating range + or - 10% Compressor RLA (total) 12.8 Condenser fan motor watts 550 Condenser fan full load amps (total) 1.5 Recommended maximum fuse (amps) 25 Unit minimum circuit ampacity 20.0 Submittal Nbr: U603Q260K0-01 Page 3 of 16 Lennox Industries, Inc. - Product Submittal ROSS D.F.L. March 28, 2000 LODI, CA DIMENSIONS Dimensions 44.8125(h) x 47.75(w) x 99.25(d) (in.) Down-flo supply air opening 15.0(1) x 28.0(w) (in.) Down-flo return air opening 15.0(1) x 28.0(w) (in.) Horizontal supply air opening 15.0(h) x 28.0(w) (in.) Horizontal return air opening 15.0(h) x 28.0(w) (in.) Total installed unit weight 1,339 (lbs.) EQUIPMENT FEATURES Durable Outdoor Enamel Paint Finish Unit Lifting Brackets Pre -charged Refrigeration System Expansion Valves High Capacity Driers Loss of Charge Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control Units will operate cooling down to 0 degrees F. (-17.7 degrees C.) AGA -CGA Certified Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Two Stage Gas Heating Aluminized Steel Inshot Burners Limited warranty on heat exchanger of 10 years Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Warranty Certificate included with unit for specific details FACTORY INSTALLED OPTIONS Blower Motor - 2 Hp Std Blower Drive Kit -1 (845-1130 RPM) Gas Heating - 125K Btuh Aluminized Steel Tubular Heat Exchanger Outdoor Air Supply - Global Economizer (FAC) Exhaust -Downflow Gravity (FAC) Return Air Smoke Detector- Factory Installed Supply Air Smoke Detector- Factory Installed Unit Disconnect 80 amps - Factory Installed GFCI - Factory Installed/Field Wired FIELD INSTALLED OPTIONS MATERIAL 14 inch Downflow Curb 17L53 Submittal Nbr: U603Q260K0-01 Page 4 of 16 Lennox Industries, Inc. - Product Submittal March 28, 2000 ROSS D.F.L. LODI, CA THERMOSTATS & CONTROLS Material FAC Novar ETM -2051 Factory Installed Rm. Sensor for Novar 97H53 Submittal Nbr: U603Q260K0-01 Page 5 of 16 Lennox Industries, Inc. - Product Submittal ROSS D.F.L. Unit ID: AC -2 SPECIFICATIONS AND RATINGS Packaged Cooling & Gas Heating March 28, 2000 LODI, CA Model number LGA036H Package Gas Unit (3 Tons) Sound rating number (db) 82.0 HEATING Heat source Natural Gas Gas supply pressure 7.0 (in. W.C.) Gas supply connection 0.5 (in.) Heating capacity input (high stage) 78,000 (Btuh) Heating capacity output (high stage) 61,600 (Btuh) AGA -CGA thermal efficiency 80.0 COOLING ARI gross cooling capacity 38,000 (Btuh) ARI net cooling 35,800 (Btuh) ARI total unit watts 3,400 ARI EER (BtuhlWatts) 10.5 ARI SEER 12.0 Entering evaporator dry bulb temperature 80.0 (deg F) Entering evaporator wet bulb temperature 67.0 (deg F) Outside air dry bulb temperature 95.0 (deg F) Gross cooling capacity 38,652 (Btuh) Sensible cooling capacity 33,761 (Btuh) Leaving evaporator dry bulb temperature 62.0 (deg F) Leaving evaporator wet bulb temperature 60.3 (deg F) Condensate drain size 0.75 fpt (in.) Refrigerant type HCFC -22 BLOWER PERFORMANCE Blower air volume 1,738 (CFM) External static pressure 0.60 (in. W.C.) Nominal blower motor 0.75 (hp) Speed Name Low Air filter quantity 2 Air filter length x width 16 x 25 (in.) Air filter thickness 2 (in.) ELECTRICAL Power supply 460 V 3 Phase Unit operating range + or - 10% Compressor RLA (total) 5.8 Condenser fan motor watts 320 Condenser fan full load amps (total) 1.3 Recommended maximum fuse (amps) 15 Unit minimum circuit ampacity 11.0 DIMENSIONS Submittal Nbr: U603Q260K0-01 Page 6 of 16 Lennox Industries, Inc. - Product Submittal ROSS D.F.L. March 28, 2000 LODI, CA Dimensions 36.5(h) x 46.5(w) x 87.5(d) (in.) Down-flo supply air opening 14.0(1) x 28.0(w) (in.) Down-flo return air opening 14.0(1) x 28.0(w) (in.) Horizontal supply air opening 14.0(h) x 28.0(w) (in.) Horizontal return air opening 14.0(h) x 28.0(w) (in.) Total installed unit weight 791 (lbs.) EQUIPMENT FEATURES Durable Outdoor Enamel Paint Finish Unit Lifting Brackets Pre -charged Refrigeration System Expansion Valves High Capacity Driers Loss of Charge Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control Units will operate cooling down to 0 degrees F. (-17.7 degrees C.) AGA -CGA Certified Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Aluminized Steel Inshot Burners Limited warranty on heat exchanger of 10 years Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Warranty Certificate included with unit for specific details FACTORY INSTALLED OPTIONS Blower Motor - Direct Drive Gas Heating - 78K Btuh Aluminized Steel Tubular Heat Exchanger Outdoor Air Supply - Manual OAD (FAC) Unit Disconnect 80 amps - Factory Installed GFCI - Factory Installed/Field Wired FIELD INSTALLED OPTIONS MATERIAL 14 inch Downflow Curb 45119 THERMOSTATS & CONTROLS Material FAC Novar ETM -2051 Factory Installed Rm. Sensor for Novar 97H53 Submittal Nbr: U603Q260K0-01 Page 7 of 16 Lennox Industries, Inc. - Product Submittal ROSS D.F.L. Unit ID: AC -3 SPECIFICATIONS AND RATINGS Packaged Cooling & Gas Heating March 28, 2000 LODI, CA Model number LGA156H Package Gas Unit (13 Tons) HEATING Heat source Natural Gas Gas supply pressure 7.0 (in. W.C.) Gas supply connection 1.0 (in.) Heating capacity input (high stage) 169,000 (Btuh) Heating capacity output (high stage) 135,000 (Btuh) AGA -CGA thermal efficiency 80.0 COOLING ARI gross cooling capacity 155,000 (Btuh) ARI net cooling 150,000 (Btuh) ARI total unit watts 13,000 ARI EER (Btuh/Watts) 11.5 ARI integrated part load value 12.6 Entering evaporator dry bulb temperature 80.0 (deg F) Entering evaporator wet bulb temperature 67.0 (deg F) Outside air dry bulb temperature 95.0 (deg F) Gross cooling capacity 153,153 (Btuh) Sensible cooling capacity 109,799 (Btuh) Leaving evaporator dry bulb temperature 58.8 (deg F) Leaving evaporator wet bulb temperature 57.1 (deg F) Condensate drain size 1.00 fpt (in.) Refrigerant type HCFC -22 BLOWER PERFORMANCE Blower air volume 4,800 (CFM) External static pressure 0.60 (in. W.C.) Required blower motor including wet coil 1.44 (hp) Nominal blower motor 2.0 (hp) Required RPM 671 RPM range 535 - 725 Air filter quantity 6 Air filter length x width 24 x 24 (in.) Air filter thickness 2 (in.) ELECTRICAL Power supply 460 V 3 Phase Unit operating range + or - 10% Compressor RLA (total) 22.2 Condenser fan motor watts 1,380 Condenser fan full load amps (total) 5.2 Recommended maximum fuse (amps) 40 Unit minimum circuit ampacity 33.0 Submittal Nbr: U603Q260K0-01 Page 8 of 16 Lennox Industries, Inc. - Product Submittal ROSS D.F.L. March 28, 2000 LODI, CA DIMENSIONS Dimensions 54.25(h) x 91.125(w) x 133.0(d) (in.) Down-flo supply air opening (2) 20.0(1) x 28.0(w) (in.) Down-flo return air opening 15.0(1) x 60.5(w) (in.) Horizontal supply air opening 14.0(h) x 75.0(w) (in.) Horizontal return air opening 15.0(h) x 60.5(w) (in.) Total installed unit weight 2,584 (lbs.) EQUIPMENT FEATURES Durable Outdoor Enamel Paint Finish Unit Lifting Brackets Pre -charged Refrigeration System Expansion Valves High Capacity Driers Loss of Charge Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control Units will operate cooling down to 0 degrees F. (-17.7 degrees C.) AGA -CGA Certified Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Aluminized Steel Inshot Burners Limited warranty on heat exchanger of 10 years Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Warranty Certificate included with unit for specific details FACTORY INSTALLED OPTIONS Blower Motor - 2 Hp Std Blower Drive Kit -A (535-725 RPM) Gas Heating - 169K Btuh 1 stage Aluminized Steel Tubular Heat Exchanger Outdoor Air Supply - Global Economizer (FAC) Exhaust -Downflow Gravity (FAC) Return Air Smoke Detector- Factory Installed Supply Air Smoke Detector- Factory Installed Circuit Breaker 40 amps - Factory Installed 0 GFCI - Factory Installed/Field Wired FIELD INSTALLED OPTIONS MATERIAL 14 inch Downflow Curb 16K87 THERMOSTATS & CONTROLS Material Submittal Nbr: U603Q260K0-01 Page 9 of 16 Lennox Industries, Inc. - Product Submittal March 28, 2000 ROSS D.F.L. LODI, CA FAC Novar ETM -2051 Factory Installed Rm. Sensor for Novar 97H53 Submittal Nbr: U603Q260K0-01 Page 10 of 16 Lennox Industries, Inc. - Product Submittal ROSS D.F.L. Unit ID: AC -4,6 SPECIFICATIONS AND RATINGS Packaged Cooling & Gas Heating March 28, 2000 LODI, CA Model number LGA12OH Package Gas Unit (10 Tons) Sound rating number (db) 88.0 HEATING Heat source Natural Gas Gas supply pressure 7.0 (in. W.C.) Gas supply connection 0.75 (in.) Heating capacity input (low stage) 84,500 (Btuh) Heating capacity output (low stage) 67,500 (Btuh) Heating capacity input (high stage) 130,000 (Btuh) Heating capacity output (high stage) 104,000 (Btuh) AGA -CGA thermal efficiency 80.0 COOLING ARI gross cooling capacity 125,000 (Btuh) ARI net cooling 120,000 (Btuh) ARI total unit watts 10,900 ARI EER (Btuh/Watts) 11.0 ARI integrated part load value 11.8 Entering evaporator dry bulb temperature 80.0 (deg F) Entering evaporator wet bulb temperature 67.0 (deg F) Outside air dry bulb temperature 95.0 (deg F) Gross cooling capacity 128,000 (Btuh) Sensible cooling capacity 90,880 (Btuh) Leaving evaporator dry bulb temperature 59.0 (deg F) Leaving evaporator wet bulb temperature 57.0 (deg F) Condensate drain size 1.00 fpt (in.) Refrigerant type HCFC -22 BLOWER PERFORMANCE Blower air volume 4,000 (CFM) External static pressure 0.60 (in. W.C.) Required blower motor including wet coil 2.22 (hp) Nominal blower motor 3.0 (hp) Required RPM 920 RPM range 680 - 940 Air filter quantity 4 Air filter length x width 18 x 24 (in.) Air filter thickness 2 (in.) ELECTRICAL Power supply 460 V 3 Phase Unit operating range + or - 10% Compressor RLA (total) 18.0 Condenser fan motor watts 700 Condenser fan full load amps (total) 2.6 Submittal Nbr: U603Q260K0.01 Page 11 of 16 Lennox Industries, Inc. - Product Submittal March 28, 2000 ROSS D.F.L. LODI, CA Recommended maximum fuse (amps) 35 Unit minimum circuit ampacity 28.0 DIMENSIONS Dimensions 50.0(h) x 58.0(w) x 99.25(d) (in.) Down-tlo supply air opening 20.0(1) x 28.0(w) (in.) Down-flo return air opening 20.0(1) x 28.0(w) (in.) Horizontal supply air opening 15.0(h) x 28.0(w) (in.) Horizontal return air opening 20.0(h) x 28.0(w) (in.) Total installed unit weight 1,453 (lbs.) EQUIPMENT FEATURES Durable Outdoor Enamel Paint Finish Unit Lifting Brackets Pre -charged Refrigeration System Expansion Valves High Capacity Driers Loss of Charge Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control Units will operate cooling down to 0 degrees F. (-17.7 degrees C.) AGA -CGA Certified Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Two Stage Gas Heating Aluminized Steel Inshot Burners Limited warranty on heat exchanger of 10 years Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Warranty Certificate included with unit for specific details FACTORY INSTALLED OPTIONS Blower Motor - 3 Hp Std Blower Drive Kit -1 (680-940 RPM) Gas Heating - 130K Btuh Aluminized Steel Tubular Heat Exchanger Outdoor Air Supply - Global Economizer (FAC) Exhaust-Downflow Gravity (FAC) Return Air Smoke Detector- Factory Installed Supply Air Smoke Detector- Factory Installed Unit Disconnect 80 amps - Factory Installed GFCI - Factory Installed/Field Wired FIELD INSTALLED OPTIONS MATERIAL Submittal Nbr: U603Q260K0-01 Page 12 of 16 Lennox Industries, Inc. - Product Submittal March 28, 2000 ROSS D.F.L. LODI, CA 14 inch Downflow Curb 53150 THERMOSTATS & CONTROLS Material FAC Novar ETM -2051 Factory Installed Rm. Sensor for Novar 97H53 Submittal Nbr: U603Q260K0-01 Page 13 of 16 Lennox Industries, Inc. - Product Submittal ROSS D.F.L. Unit ID: AC -5,7 SPECIFICATIONS AND RATINGS Packaged Cooling & Gas Heating March 28, 2000 LODI, CA Model number LGAI8OH Package Gas Unit (15 Tons) HEATING Heat source Natural Gas Gas supply pressure 7.0 (in. W.C.) Gas supply connection 1.0 (in.) Heating capacity input (low stage) 169,000 (Btuh) Heating capacity output (low stage) 135,000 (Btuh) Heating capacity input (high stage) 260,000 (Btuh) Heating capacity output (high stage) 208,000 (Btuh) AGA -CGA thermal efficiency 80.0 COOLING ARI gross cooling capacity 188,000 (Btuh) ARI net cooling 182,000 (Btuh) ARI total unit watts 15,800 ARI EER (Btuh/Watts) 11.5 ARI integrated part load value 13.3 Entering evaporator dry bulb temperature 80.0 (deg F) Entering evaporator wet bulb temperature 67.0 (deg F) Outside air dry bulb temperature 95.0 (deg F) Gross cooling capacity 188,100 (Btuh) Sensible cooling capacity 135,432 (Btuh) Leaving evaporator dry bulb temperature 59.1 (deg F) Leaving evaporator wet bulb temperature 57.3 (deg F) Condensate drain size 1.00 fpt (in.) Refrigerant type HCFC -22 BLOWER PERFORMANCE Blower air volume 6,000 (CFM) External static pressure 0.60 (in. W.C.) Required blower motor including wet coil 2.07 (hp) Nominal blower motor 3.0 (hp) Required RPM 718 RPM range 535 - 725 Air filter quantity 6 Air filter length x width 24 x 24 (in.) Air filter thickness 2 (in.) ELECTRICAL Power supply 460 V 3 Phase Unit operating range + or - 10% Compressor RLA (total) 27.0 Condenser fan motor watts 1,380 Condenser fan full load amps (total) 5.2 Recommended maximum fuse (amps) 45 Submittal Nbr: U603Q260K0-01 Page 14 of 16 Lennox Industries, Inc. - Product Submittal March 28, 2000 ROSS D.F.L. LODI, CA Unit minimum circuit ampacity 39.0 DIMENSIONS Dimensions 54.25(h) x 91.125(w) x 133.0(d) (in.) Down-flo supply air opening (2) 20.0(1) x 28.0(w) (in.) Down-flo return air opening 15.0(1) x 60.5(w) (in.) Horizontal supply air opening 14.0(h) x 75.0(w) (in.) Horizontal return air opening 15.0(h) x 60.5(w) (in.) Total installed unit weight 2,592 (lbs.) EQUIPMENT FEATURES Durable Outdoor Enamel Paint Finish Unit Lifting Brackets Pre -charged Refrigeration System Expansion Valves High Capacity Driers Loss of Charge Switch High Pressure Switch (Manual Reset) Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control Units will operate cooling down to 0 degrees F. (-17.7 degrees C.) AGA -CGA Certified Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Two Stage Gas Heating Aluminized Steel Inshot Burners Limited warranty on heat exchanger of 10 years Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Warranty Certificate included with unit for specific details FACTORY INSTALLED OPTIONS Blower Motor - 3 Hp Std Blower Drive Kit -A (535-725 RPM) Gas Heating - 260K Btuh Aluminized Steel Tubular Heat Exchanger Outdoor Air Supply - Global Economizer (FAC) Exhaust -Downflow Gravity (FAC) Return Air Smoke Detector- Factory Installed Supply Air Smoke Detector- Factory Installed Circuit Breaker 45 amps - Factory Installed 0 GFCI - Factory Installed/Field Wired FIELD INSTALLED OPTIONS MATERIAL Submittal Nbr: U603Q260K0-01 Page 15 of 16 Lennox Industries, Inc. - Product Submittal March 28, 2000 ROSS D.F.L. LODI, CA 14 inch Downflow Curb 16K87 THERMOSTATS & CONTROLS Material FAC Novar ETM -2051 Factory Installed Rm. Sensor for Novar 971153 Submittal Nbr: U603Q260K0-01 Page 16 of 16 JUN -07-2000 11:08 Lamp Systerris F32 • F40 • FS6 Reduced Harmonics (RH, RHH} Low Wattage (Li E High Performance (HP. HPH, HPL Diagram 15 a•••rw BALLAST + UMP Diagram 3a �••° BALLAST + LAMP LAMP Mao far o• loop.ppaewek oaf as bin toed, Yaoloo m eal.eita Diagram 4 • BALLAST + n • • 1 LAMP •• 1 LAMP '' - I LAMP -_ Nor Forma loop appliearion, cop row tiler wabaa fraWlt Imolot° a aewla Diagram 5 . + l BALLAST UMW UMP LAMP i-� Markt twe hoot upe.w+ ea, .. thee bed, Iea.l.r.ariWm P. 3 F3Z1'8 PARIS 1211 B3321120RH 80112 87 .88 74 .98 <20 0°F 5 277 B3321277RH 80113 87 .88 32 ,98 <20 0°F 5 120 83321120RHH 80130 113 1.18 .97 .98 <20 50°F 5 277 B3321277811H 80131 113 1.18 .42 .98 <20 0°F 5 120 1332211201. 80124 77 ' .78 ° .65 .98 20 0°F 5 277 83321277E : 80125 71 .78 • .28 98 <20 0°F 5 120 'r 21120HP Si a 277 347 PAR -RS 120 . 32R112GHP a�+ 711 itt .,:ilii PAR -IS 120 84321120RH 277 84321277RH PAR -IS 347 PARIS 120 277 120 ! itfiHP m PAR -RS 120 277 4 F3T8 PAR -IS 120 8432112884 277 1143212771*1 80115 113 .88 .42 120 84321120L 80126 100 .78 .85 277 134321277E 120 I81321120HP e8108 1141.88 277 277HP. 347 � B4321347HP�, PAR -RS 120 B432R120N 277 "B... .1 IP I. ,..... =121 8 _ .99 :. c 10,, :50°F "6 4 Fb'12 PARIS 120 84321120RH' 80114 95 .83 .81 .98 <20 10°F 1 "Tr 00146P 277 134321217RH' 80115 94 .83 .35 .98 <20 10°F 7 1.01. d Cu gown .eedha. See pp.' for mon iN.mni•n my WM ryn•mc 81321120E 13432127X 80114 93 .95 80115 93 .95 .35 .80 .97 <20 50°F 7 .97 <20 50°F 7 80126 83:.86 .71 ' ,97 <20 50°F 7 80127 83 .86 31 " .97 <20 50°F 7 80114 114 .88 .97 80127 100 .78 37 .98 .98 .98 .98 <20 50°F 7 <20 50•F 7 <20 50°F 7 <20 50°F 7 Gaaual Appierin New • Far Melons' product orap edamron.Oleos caO1. GFBAl1ASf. • amodels room savilardaucr.t=volt • Al modal. °n UL %Mod or Component Racorlead soma SU volt • Al modals °r. CBM eardkd.Wawa apok.bIL • !domain mounted here 4 typical and moral per ANSI standards K read Me vamp and ram amparon Whiled prfamrwad.a mayv.ry by sopica an. • Lamp Dar mCrutPolars for 'ISE Mende Balm wooly vat ANSI C82 sandarac. • All nad&MAwe aSound Reim 'UANA., • S.acBeatlansire saq.etmdells MhoutliodelL Energy Cost � ing Loweringyriur lighting power bill will also lower your airetoknditionin On average, every watt you take out of the lightingsystem will saysyou'h waft in air conditioning. One more reason to switch to GE Electronic Ballasts. 10 JUN -07-2000 11:09 P.03 2 F32TB PAR -15 120 277 220 120 277 120 277 120 277 347 PAR -RS 120 277 PAR -IS 120 277 120 277 120 277 347 PAR -RS 120 277 SER -RS 120 m 120 277 120 277 2 F25T12 PAR -1S 120 "T$ 277 B2321120RH 80110 58 .88 .49 .98 <20 0°F 3a B2321277RH 80111 58 .88 .21 .98 <20 0°F 3a B2321220RH 80172 59 .88 .28 .96 <20 0°F 3a B2321120RHH 80128 76 1.18 .65 .96 <20 0°F 3b B2321277RHH 80129 76 1.18 .28 .98 <20 0°F 3b B2321120L 80122 51 .78 A5 .96 <20 0°F 3e 823212771 80123 51 .78 19 .98 <20 0°F 3a B2321120HP • 80102 59 .88 .50 .99 <10 0°F 3a B2321277HP 80103 59 .88 22 .99 <10 0°F 3a B2321347HP 80135 59 .88 .17 .99 <10 0°F 3a B232R120HP 80116 63 18 .53 .99 <10 50°F 2a 8232R21711P 80117 63 .88 .23 .99 <10 50°F 2a B3321120RH 90112 65 .98 .55 .98 <20 0°F 5 B3321277RH 80113 65 .98 .24 .98 <20 0°F 5 B33211201 80124 58 .86 .50 .97 <20 0°F 5 833212771 80125 58 .86 .22 .97 <20 0°F 5 83321120HP 80104 66 .98 .56 .98 <10 0°F 5 B3321277HP 80105 66 .98 .24 .98 <10 01 5 B3321347HP 80136 66 .98 .19 .98 <10 0°F 5 8333120HP 80118 68 .98 .58 .96 <10 50°F 4 6332R277HP 80119 68 .98 15 .98 <10 50°F 4 B232SR120V20 80140 63 .52 .99 <10 50°F 18 Performance at 20% 20 .17 .17 .90 <15 82325R277V20 :1141 63 .8B .23 .99 <10 50°F 18 Performance at 20% 20 .17 .08 .90 <15 B232SR120S50 80180 62 .53 .99 <10 50°F 21 Performance at 50% 37 .48 31 .95 <10 B232SR277S50 80181 62 .23 .99 <10 50°F 21 Performance at 50% 37 .48 .14 .95 <10 8232SR120S30 80176 62 .88 .52 .99 <10 50°F 21 Performance at 60% 45 .58 .38 .95 <15 Performance at 3096 28 .27 .24 .95 <15 8232SR277530 80177 62 .88 .23 .99 <10 50°F 21 Performance at 60% 45 .58 .17 .95 <15 Performance at 30% 28 27 .11 .95 <15 82321120RH' 80110 48 .83 .41 .95 <20 0°F 3a B2321277RH' 80111 47 .83 .17 .95 <20 0°F 3a - UL and CSD. appeq °aaeiN. sez your curant system asa iactrpmagns....:s,,:�s:s' if so, saiviicninq to GE's r".educed ;-iarmonic iR;H) 3ailas:s ,TE3 -Mil improve your power qualirf. In a ?e lr applications wit unusu 311V S:rin6aa:Lt power quality needs, .]C 3Tfsrs iRi h Psrformanc3 (HP) 3ailas:s (THO 9 Abbreviate= RS • Rapid Start PAR • Parallel Lamp Operation IS • MOM Start SER - Series Lamp Operation Diagram 5 .W. BALLAST m tT - UMP i I T=om LAMP •=l UMP (-• Nes mor1w. Imp applkaion.v►aarr Mug Met issulate BM wIlb. Diagram 18 Ni. Ballard curs mos M Bna°d°d. Diagram 19 ue to* LAMP 1== Nur. Wm °am eerrba pwedai Diagram 20 M BALLAST 1°;-• LAMP I Nee Salim Casa numbs rounded. Diagram 21 e o+ SWAM. BALLAST s • I LAMP I- , . UMP I_ Now WW1 co. em bepwedai JUN -0? -2000 11 10 nnappllption and erlvuon i.et',,I,—....,_,, ;. OSRAM S!LYJINW "" 1 ) 'i" " ' r ani.Q1aIl .c^^''Ord it^ OSRA Energ TzEC (Intenvittinia: SYLY K'%rR4.!�y� P. 1.111 MOWN ON 01•4111411. MUM mop ptllWlrt�wnenay ieing •'wit. .. . Iv. ji. or Englneereig society of North Amato (IES) through The HM daH preeerded fn this 110iog Mil/erodes SYLVANIA : The Leader In Saving Fluorescent Lamps The fluorescent Tamp isn electric discharge device which utilizes a low presaure mercury vapor arc to generate ultra -violet (plu a little visible) energy. The ultra -violet energy is abs rbed by a phosphor coat on the inside of the glass to e and converted by the phosphor to visible wave engths; the wavelengths of the Tight generated are determined by the composi- BULB PHOSPHOR Usually straight glass] Coating inside the bulb tuba. May also be drqular teanstorms ultraviolet or U-shaped. II radiation into visible light. Color of light pro- duced depends an com- position o' phosphor. BASE Several different types used to connect the lamp to the electric cir- cuit and to support the lamp in the lampholder. MERCURY A minute quantity of liq- uid mercury is placed in the bulb to furnish mer- cury vapor. 7rSAS Usually argon or a mix- ture of Inert gases at low pressure. Wypton is sometimes used. tion of the phosphor. In addition to the small amount of mercury vapor, the fluorescent tube contains an atmosphere of an inert gas, usually argon, krypton, neon, or a mixture of two or more of these gases. The pressure of the gases contained in the Tamp is very low, usually from 2 to 3 torr. Atmospheric pressure is 760 torr. CATHODE "Hot cathodes" at each end of lamp are coated with emissive materials which emit electrons. Usualty made of coiled - coil or single -coil tung- sten wire. How to Read ordering Guide 20 T-12 24" Med. Bipin A A A Nominal Length ease Watts One Item No. Bulb for each lamp T-12 —Tubular V Diameter EXHAUST TUBE Air is exhausted through this tube during manu- facture and inert gas introduced Into the bulb. STEM PRESS The lead-in wires have an air tight seal here and are made of spectilc Matto assure about the same coetllciem of expansion as the glass. LEAD-IN WIRES Connect to the base pins and carry the current to and from the cathodes and the mercury arc. Package Quantity � Description 22075 F20712/0830 -41— 30 Designer "800" 3000K 9000 22018 FZ0712/B 6 Blues' 9000 22078 F20712/CW 30 Cool White 9000 22029 F20T12/GRO/AG/R12 GRO-LUX®Aquarium Retail Pack X 9000 Footnotes } F20T12/0030 --011— F— F — Fluorescent 20— Nominal Warts T— Tubular Shape 12 —'3P (1 %) Diameter D830 -- Phosphor Coating Color Average Rated Hours of Life 1350 550 1240 Approx InhW Lumens • • JUN -07-2000 11:11 T-8 SINGLE PIN ;; . t : r;€t1 T-8 q,.z�tSifi..,,y} 4.N' ._;.w'iti� • Via' t`.110% at3i#V7 P. 05 OCTRON®, OC "700" SERIES Note: OCTRON, Lamps should be op lasts that are either Instant start or last factors ranging from a minimum start mode, the two wires or two can wire using National Electric Cade to OCTRON® "700" SE RON® CURVALUME® "800" SERIES rated only with magnetic rapid start ballasts designed to operate 265 ma, T-8 lamps or high frequency (electronic) bal- pid start specifically designed to operate 11 lamps. OCTRON lamps may be operated on instant star) ballasts with bai- t 0.77 to a maximum of 1.20 at the nominal ballast input voltage. When DCTRON• lamps are operated in the instant cta of each socket shoald be connected to each other. They should then be connected to the appropriate ballast lead niques. Approximate length al Octron• Curvalume• lamps Is measured from base face to outside at glass bend. IES 17 T-8 24" ,Vendor ID NO. OC1046135 _ '^ ; UPC 46135 • a;:'sq tamp: ': item No. Ordering Abbreviation Med. Blpi 21849 F017/730 21832 F017/735 21831 F017/741 Med. Bipir) 21851 F025/730 21817 F0251735 21829 F025/741 Med . BlpiO (E) 21852 OT2/730 (E) 21997 F0321730/ECO 21957 F032/730/PLT (E) 21823 F032/735 F032/735/ECO F032/735/PLT _ F032/741 F0321741/ECO F032/741/PLT F032/750 F032/765 F032/735/GUARDED F032/GOLD F040(730 F040/735 F040/741 F096/730 F096/735 F096/741 1 1 , 25 T-8 36" 32 T-8 48" 21998 21959 (E) 21824 21999 21966 (E) 21809 I () 21993 21934 21961 40 T-8 60" Med. Bipirl 21853 21820 21827 59 T-8 96" Single Pini 21854 21839 21840 OCTRON® "800" SERIES 17 T-8 . 24" Med. Bipi ' 21978 21882 21883 21884 25 T-8 36" = Med. Bipin; 21979' 21886 21887. .21888 32 T-8 48". - Med: Bipin,? : 21955 ._. 21890 . . 21777 "'.21760 Pkg.' Qty. 30 30 30 30 30 30 30 30 1968 30 1968 30 30 1968 '40 30 30 30 30 30 30 24 24 24 Description 3000K, 75 CRP 3500K, 75 CHIS 4100K, 75 CRP 3000K, 75 CRP 3500K, 75 CRI23 4100K, 75 CRI" 3000K, 75 CRI23 3000K, 75 CRI23, ECOLOGIC 3000K, 75 CRI23 Pallet Pack 3500K, 75 CRP 3500K, 75 GRP, ECOLOGIC 3500K, 75 CRI23, Pallet Pack 4100K, 75 CRI23 4100K, 75 CR127, ECOLOGIC 4100K, 75 CR123, Pallet Pack 5000K, 75 CRP 6500K, 75 CRI23 3500K, 75 CRP,Shielded lite Avg. Rated Hours (21) 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 1800K, Gold Filtered, Shielded30 20000 3000K, 75 CRP 20000 3500K, 75 CR123 20000 4100K, 75 CR123 20000 3000K, 75 CRP 15000 3500K, 75 CRl25 15000 4100K, 75 CR12S 15000 Ught Output APprox. Lumens(2) 1325 1325 1325 2050 2050 2050 2800 2800 2800 2800 2800 2800 2800 2800 2800 2650 2750 2400 1700 3550 3550 3550 5700 5700 5700 F017/827 ®- 30 2700K, 82 CR123 20000 1300 F017/8311 : 30 . 3000K, 82 Cli123 20000 1400 F017/835 • 30- ' 3500K, 82 CR123 20000 1400 . F017/841 - 30 : 4100K, 82 CRI" 20000 1400 • ., F025/827 e • 30, . 2700K, 82 CRI23 20000 1860 F025/830 .,," . . 30 3000K.82 CRP 20000 2225 F0251835 F.:, .30.:1 3500K, 82 CR123 20000 2225 F025/841 .. , 30 4100K, 82 CRP 20000 2225 F032/827 ® .30:,. 2700K, 82 CRP 20000 2580 F032/830 . 30' 3000K, 82 CRI23 20000 2950 F032/830/EC01,.:... ' . , . 30.:) 3000K, 82 CRI23, ECOLOGIC 20000 2950 . '' F032/830/XP..ti--= .. It:. A0 3000K, 85 CRI 24000 3000 EXTENDED PERFORMANCE(2820 mean Lumens)" means this bulb meets Federal -minimum efficiency standards. CD Energy Saving ProductNalue ed Product n High Color Rendering Lamp ® New Ltem Footnotes/Symbols pages 167-169 JUN -07-2000 11:1.3 DIMENSIONS 16/1r-7Mem] 125/9• (321mm) ORDERING INFORMATION SAMPLE NUMBER: CX717OR Family CX -Die Cast Aluminum Exit Serino 7.Self-Powered. LED Face Option. 1.5ingle 2 -Double Energy Date LED Exits -Red Letters LED Exits -Green Letters 4VV rit„non, 1 1 1 0• L 27mmi I . 1 1 I I Battery Letter Cairns Housing Aeeawtir 70.Nickai R.Red Fbiishu cAx-ta-PKIL.lr Pendant Kit. Black 5i Cadmium G.Green Blink. CAX•1KWH.18• Pendant Kit.Whit, Battery Bruahed VS1.Polycarbonate Vandal Shield Aluminum Mali Mount Only) Face with VS1 WP -Wether Resistant Black Polycarbonate Vandal Shield Housing (Wall Mount OnlyI-W White WG10.Wire Guard (Wall Mount Onlyl B.Black WGS-1t.Wire Guard (Ceiling or End Mount Only) DESCRIPTION The CX LED Die Cast Aluminum Exit combines the strength and durability of die casting with the bright even illumination of LED lamp sources. Unlike competitive units that have a pronounced dot effect from protruding diodes, the CX LED offers unequalled uniform illumination and brightness. Input Power Input Current (Max.): 20V 277V 120V 277V MINN .0W 2AW .OSA .D2A I.SW 3.6W .OSA .04A Power Fectar. T.H.D.: 120V 2771/ 120V 277V a.91 a,,7 x32% c46 a .41 ..43 c 48% c 49% P.06 CX SERIES Cast Aluminum Exits Surface Mount Self -Powered Led Lamps EXIT LIGHTING • Dual Voltage input 120/277 VAC, 60 Hz • Push -in AC power connectors facilitate installation Line -latching, solid-state voltage limited charger, low voltage disconnect, brownout circuit, over- load/short circuit protection, test switch/ power indicator light • Die cast aluminum housing • Die cast canopy included • Universal pattern knock- outs on rear of single face housing for direct mounting to junction box • Knockout provided on housing for surface attachment • Exit can be universally mounted ceiling, wall or end NFPA 101 compliant knockout chevrons allow quick conversion to directional signs LED lamp provides uniform light output • DC: LED Lamps UL 924 Listed, CSA Certified, Life Safety NFPA 101. NEC/OSHA, most state and local codes, suitable for floor proximity installation COOPER LIGHTING RESOLUTION NO. 2000-128 A RESOLUTION OF THE LODI CITY COUNCIL AUTHORIZING THE CITY MANAGER TO PROVIDE A PUBLIC BENEFITS PROGRAM GRANT TO ROSS DRESS FOR LESS WHEREAS, the State has mandated that beginning January 1, 1998, the City of Lodi is obligated to fund various programs through a Public Benefits Charge (PBC) based on a historical electric revenue requirement; and WHEREAS, the requirement amounts to approximately $1M per year that must be dedicated to qualifying programs such as energy efficiency. A further stipulation is that these efforts must be done on the customer's side of the meter in order to qualify; and WHEREAS, a new business in Lodi, Ross Dress For Less has elected to participate in the City of Lodi Public Benefits Program. As the new tenant at 340 W. Kettleman Lane (formerly the site of Luckys Grocery Store), Ross Dress For Less has conducted numerous tenant improvements to the structure, including several energy efficiency improvements. Specifically, Ross Dress For Less has had installed: > seven (7) high efficiency heating & air conditioning- HVAC- units (energy efficiency rating of 10.2 or better for all units; the highest rated unit is a 12.6, 13 -ton unit); D over 1,900 T8 fluorescent lamps with electronic ballasts; and • seven (7) LED technology EXIT signs. WHEREAS, by installing these high efficiency products and pieces of equipment, Ross Dress For Less can anticipate a 10% to 15% savings on their monthly electric utility bill, versus the old, inefficient equipment recently replaced. Ross Dress For Less is considered a national leader (a retail chain that operates stores from coast-to-coast) in the utilization of energy efficient products and materials, including HVAC units, lighting and energy management systems; and WHEREAS, after numerous meetings and site visits, the City of Lodi Electric Utility respectfully recommends approval of this grant as a qualifying component of the City of Lodi Public Benefits Program. NOW, THEREFORE, BE IT RESOLVED, that the Lodi City Council hereby authorizes the City Manager to provide a Public Benefits Grant in the amount of $15,869.75 to Ross Dress For Less. Dated: July 19, 2000 I hereby certify that Resolution No. 2000-128 was passed and adopted by the Lodi City Council in a regular meeting held July 19, 2000 by the following vote: AYES: COUNCIL MEMBERS — Hitchcock, Land, Nakanishi, Pennino and Mann (Mayor) NOES: COUNCIL MEMBERS — None ABSENT: COUNCIL MEMBERS — None ABSTAIN: COUNCIL MEMBERS — None SUSAN J. BLAC ON City Clerk 2000-128