HomeMy WebLinkAboutResolutions - No. 91-54RESOLUTION NO. 91-54
A RESOLUTION OF THE LODI CITY COUNCIL
APPROVING TITLE CHANGE AND REVISED CLASS SPECIFICATIONS
OF ELECTRIC TROUBLEMAN TO ELECTRIC TROUBLESHOOTER
.RESOLVED, that the Lodi City Council does hereby approve the
title change and revised class specifications of Electric Troubleman to
Electric Troubleshooter, as shown on Exhibit A attached hereto.
Dated: March 20, 1991
I hereby certify that Resolution No. 91-54 was passed and
adopted by the Lodi City Council in a regular meeting held March 20,
1991 by the following vote:
Ayes: Council Members - Pennino, Pinkerton, Sieglock, Snider
and Hinchman (Mayor)
Noes: Council Members - None
Absent: Council Members - None
/k
Alice M. RemcheZk
City Clerk
91-54
RES9154/TXTA.02J
_ - - -- - marcn ZU,�t�991 r�
ELECTRIC TROUBLESHOOTER IillS1[.±lie�:llTf s�i1
DEFINITION:
Under general direction performs skilled work in troubleshooting electric
distribution systems. Installs and maintains services and lighting systems;
locates underground facilities; supervises Electric Lineman/Linewoman as
assigned; performs various record keeping tasks and does related work as
required.
DISTINGUISHING CHARACTERISTICS:
The class of Electric Troubleshooter is distinguished from the lower class
of Electric Lineman/Linewoman in that this position works independently with
limited supervision and may provide supervision of an Electric
Lineman/Linewoman, or others, as assigned. The Electric Troubleshooter is
expected to possess thorough working understanding of and the skills
necessary to troubleshoot electric distribution systems as well as the
ability to maintain records and organize the work day, in addition to
knowledge of rules, regulations and safety practices. This position
extensively interacts with the general public and customers under various
conditions and is expected to perform in a most courteous and professional
manner even under adverse conditions. This position may work a staggered
schedule, including Saturday, and is on a rotational standby duty (one week
periods) for after-hours call back work.
SUPERVISION RECEIVED AND EXERCISED:
Receives general supervision from the Electric Utility Superintendent or
designee. Exercises supervision of Electric Lineman/Linewoman or others, as
assigned.
(i EXAMPLES OF DUTIES:
Duties may include, but are not limited to, the following:
First line troubleshooting of electric system.
Diagnoses, locates, and clears trouble on primary and secondary overhead and
underground lines and streetlighting systems.
Participates in switching operations of the system and obtains loading data
for system studies.
Runs new services from poles, transformers or service boxes to customer
facilities; connects and disconnects services, troubleshoots and tests
individual customer services.
Installs electric meters at new customer locations.
Installs underground service conduits.
Performs streetlighting and dusk -to -dawn lighting repair, maintenance and
installation.
Locates underground facilities per "USA" requests.
Performs many of the above functions on energized systems utilizing
appropriate tools and techniques.
Maintains tools and equipment in a clean and workable condition.
Inspects overhead and underground systems for conformance to state
electrical safety orders (G.O. 95 & 128), and other applicable rules
and regulations.
Performs a wide variety of record keeping tasks, such as meter set records,
service orders, material records, temporary service records, etc., and
prepares time cards.
CITY OF LODI
ELECTRIC TROUBLESHOOTER
MINIMUM QUALIFICATIONS
Knowledge of:
Page 2 of 3
Methods, materials and equipment used in construction, maintenance and
troubleshooting of overhead and underground electric distribution and
transmission systems.
Principles of electrical theory as applied to power systems.
Transformer and other equipment connections for various applications.
Applicable electrical codes and regulations, such as State electrical safety
orders (e.g. G.O. 95 and 128), National Electric Code, etc.
Necessary precautions in working high-voltage lines.
Safe work practices and procedures including first aid and cardiopulminary
resuscitation (CPR).
City rules, regulations, construction specifications and operating practices.
Ability to:
Climb poles and use aerial buckets in confined areas among energized
overhead lines and equipment at a considerable distance above ground.
Work with energized underground 15-kv materials and methods.
Work proficiently with hot-line tools, i.e. sticks under energized
conditions on both 15-kv overhead and underground systems.
Use good judgment and take effective courses of action in emergencies.
Analyze an electrical problem, and develop and implement a series of steps
that will lead to a successful resolution.
r Work without direct supervision.
Maintain accurate and precise records in legible handwriting.
Deal tactfully in an effective and courteous manner with the general public
and other employees.
Establish and maintain a cooperative working relationship with other
employees and the general public.
Read and interpret plans and written instructions.
Supervise the work of Electric Linemen/Linewomen or others, as assigned.
Maintain good housekeeping in and around the work site.
EDUCATION AND EXPERIENCE
Any combination equivalent to education and experience that would likely
provide the required knowledge and abilities would be qualifying. A typical
combination is:
Education:
Equivalent to completion of high school.
Experience:
Possession of journey level Electric Lineman/Linewomen status granted
through the I.B.E.W. or equivalent, and two (2) years of relevant experience
in this status.
C'ITY OF LODI Page 3 of 3
ELECTRIC TROUBLESHOO__A
RESPONSE REQUIREMENT
CMust be able to meet a 20 -minute response requirement.
LICENSES AND CERTIFICATES
Possession of a valid Driver's License (Class C) issued from the California
Department of Motor Vehicles. Prior to permanent appointment, the
appropriate Commercial Driver's License with endorsements, as mandated by
the State of California Commercial Vehicle Code.
JOBSPE57/TXTA.04P/REC.DIR