Loading...
HomeMy WebLinkAboutAgenda Report - February 18, 1998 E-05CITY OF LODI COUNCIL COMMUNICATION AGENDA TITLE: Authorize Issuance of Bid Specifications for Electric Utility Materials for Capital Construction Project MEETING DATE: February 18, 1998 SUBMITTED BY: Electric Utility Director RECOMMENDED ACTION: That the City Council authorize the Electric Utility Departmentto advertise for bids of various overhead construction materials outlined in Attachment A. BACKGROUND: Woodbridge Irrigation District (WID), in order to provide electric services, may solicit construction bids or enter into other arrangements pursuant to their procedures. If the City of Lodi hopes to be a provider of the construction services, then it is incumbent that materials be readily available to meet critical construction milestones. In the event the City is selected for the contract, and the Council approves the arrangement, materials must be readily available to meet WID's schedule. Staff is recommending that the City advertise forbids in anticipation of this project, in addition to the 230/60kv and Cluff feeder needs. The construction contract for the Woodbridge project will be brought to Council for approval prior to awarding any material purchases. Should the construction contract between the City of Lodi and WID not be executed, then the materials for that project will not be purchased. All bids will be brought to the City Council for approval and award. FUNDING: Electric Utility Department Operating Fund Estimated Cost: $450,000-$675,000 F, Fog, W-m'07,'WAMINA Alan N. Vallow Electric Utility Director Funding Approval: Vicky McAthi , Finance Director Prepared by: Nancy Bougher, Senior Electric Utility Rate Analyst ANV/NBAst c: City Attorney Manager, Engineering and Operations POLE LINE HARDWARE I, MATERIAL LIST Crossarm, Wood, 9'6" LSP Treated (115-8499) Crossarm, Wood, 9'6" HSP Treated (115-8500) Line Post Stud (115-9310) Post Insulator Stud 60" Angle Vee Brace (115-9311) (115-9460) #715.5MCM Bare Aluminum Conductor #954MCM Bare Aluminum Conductor #715.5 Dead End Shoe (118-0516) #715.5 AL Tension Sleeve (118-2055) #715.5 AL Jumper Sleeve (118-2072) 15kV Post -Tie Top Insul. ANSI 57-1 (118-5045) 715.5 2 7/8" Dia. Wraplock Tie F-neck(118-7317) 715.5 2 7/8" Dia. Side Tie F -neck (118-7324) 397-954 to 397-954 AS P.G. Clamp (218-0930) 954MCM AL Jumper Sleeve 60kV Horiz. Line Post Insulator 60kV Horiz. Silicon Insulator 954-1033.5MCM AA Line Guard Insul. Standoff Brkt. Horz. 15" 954-1033.5MCM Saddle Clamp 55' Wood Pole (CL -1) 60' Wood Pole (CL -1) 55' Wood Pole (CL -3) 45' Wood Pole (CL -3) 65' Wood Pole (CL -1) 200 20 450 700 220 180,000 ft. 145,000 ft. 125 65 40 730 750 50 20 (218-2097) 10 (218-5110) 550 (218-5115) 606 (218-7232) 575 (218-8621) 600 (218-8634) 610 H:\USER\KFAWCETT\KFAWCETT\INTERCON\HARD2.WPD 63 13 12 5 8 ATTACHMENT A See Attachment 1 See Attachment 2 Joslyn J25249.3 Kortick K8366SPL Joslyn J25248.1 Joslyn J1510 McGraw DB21.1 Code Name VIOLET Code Name MAGNOLIA Anderson ADE -98-N Bethea ASD -58-N Bumdy YTS -39A Bumdy YNS-43R Chance C903-1011 Lapp 9325-70 Victor 2025 Preformed WTF-0227 Dulmison LTF-2435 Preformed STF-1163-P Bumdy UP45R Anderson LCU-16-XB Fargo 40119 Bumdy YCS431A See Attachment 3 Reliable H222037AX00 Preformed MG -0157 Slacon 80768 CFW 13-1154 Lindsey 4231 Bethea HBB-10-15 Lapp 47115 Continental LPS-200 Anderson TSC -200 �— 3 3/4„ 114" 106" 60"- 42 to- B 0"- 42" - ATTACHMENT 1 e 1B I e Is IB ----•- — �— -- — -- - • — 1 7/8" TOP n N 99" 56" m r 4 3/4" 48" e A 9 a IS A e 2 3/8" ,45' (TYR 3/8" 4 3/4" --� 3 3/4" �— D ETA I L "A" M 0) N O Ln f 7 N SIDE SEE DETAIL "A" HOLE DATA HOLE DESCRIPTION REQ'D A 0 9/16" 2 B 0 11/16" 1 1 H:\DATA\CAD\STANDARD\EES\9LTF'l. DWG ENGINEERING STANDARD CITY OF LO D I ' CROSSARM DETAIL 9 —fiM MEcTRIC unU7Y DEPAMEW LIGHT STEEL PIN 2WR97 BA AMS/DJC SNEET 1 Dr DATE DRAWN DESIGNED CNEdcED APPROVAL RENSION EES- T _„ j3/40"' I 8 2 3/8" ATTACHMENT 2 114" 106" 60"- 42"- tl n le 18 BI TOP - o r`) N 99" 56" — ~'� 3/4„ 48,E �— B B B B JA B 2 7/8" - - rn 0) N O rn N SIDE 45' SEE DETAIL "A" �(TYP) 3/8" 5 3/4" --� 4 3/4" DETAIL "A" H OLE DATA HOLE DESCRIPTION REQ'D A 0 9/16" 2 B 0 11/16" 11 H:\DATA\CAD\STAN0ARD\EES\9HVFT. owl- CITY Wu jQ= CITY OF LO D I ENGINEERING STANDARD CRO �'`•��'.e E�c�ic �� °�'�� SSARM DETAIL 9'-6" HEAVY STEEL PIN 23APR97 BA AMS/DJC SHEET or 1 DATE DRAWN DESIGNED CHECKED APPROVAL REVISiD, EES- 114" ES 3/4'-10 UFS -2B TAPPED HOLE (PER ANSI C29-7) ';/as' cnin unuNnmr: 69KV HORIZONTAL UNE POST INSULATORS • LEAKAGE DISTANCE • DRY ARCING DISTANCE • CANTILEVER LOAD • IMPULSE FLASHOVER POS. & NEG. • CONSTRUCTION PORCELAIN 45 INCHES(MIS) 17.25 INCHES(MIN) 2800 POUNDS(MIN) 290KV(MIN) PORCELAIN ATTACHMENT 3 • INSULATOR COLOR TO BE LIGHT GRAY (ANSI -70) • BRAND NAME ON INSULATOR • TRUNNION & FITTING WITHOUT CONDUCTOR CLAMP (PER ANSI C29.7) H:\DATA\CAD\ENG\TF\NIKE\PORGELAdN.DWG 1 •t ENGINEERING STANDARD -CITY OF LODI 69KV HORIZONTAL POST ELECTRIC IMUT r DEPARTMENT INSULATOR (PORCELAIN) VpYn1�98 TF MH I I SHEET 1 OF 1 xx DATE DRAWN DESIGNED T CHECKED APPROVAL REVISION