Loading...
HomeMy WebLinkAboutAgenda Report - July 5, 1984 (127)5" FIRE IME W NINICU OF 00=11, NIMBER OLSCN. PIMMUM BLOC). CaMIL SPECIFICATICNS APPFVVFD MiE SPECIFICATICI\S FM 5" HOSE FCR 11iE FIRE DEPART - (i APPrCVED NEIr AND AIM CR I ZED 111E ADVERT I S ING FCR BIDS 1I IERBC 1. gg §4.w . x �c (s; ; F �2` 3 3 yF Flt f N11 Y ' r �- 1- CITY. OF LODI SPECIFICATIONS FIVE (5) INCH LARGE DIAMETER HOSE AOSE CONSTRUCTION: 4 1. Outer ply (cover): Synthetic Nitrile Rubber a. Ultimate tensile strength: Not less than 1500 p.s.i. b. Ultimate Elongation 600% minimum 2. Center ply (reinforcement): 100% synthetic continuous polyester fiber or 100 % high tensile yarn circular plain woven to eliminate left hand twist. 3. Inner ply (lining): Synthetic Nitrile Rubber a. Ultimate tensile strength not less than 1500 p.s.i. b. Ultimate elongation 600% minimum ACCELERATED AGING TEST: 1. The tensile strength and ultimate elongation of specimens which have been subjected to the action of oxygen at a pressure of 300 + 10 p.9.1.9 and a temperature of 70 + 1 degrees C (158 + 1.8 degrees F) for a period of 96 hours shall not be less than 50% of the tensile strength and ultimate elongation of specimens which have not been heated in oxygen. ABRASION RESISTANCEi 1. Hose shall withstand a minimum of 20,000 cycles of the tabor abraser without damage to the synthetic reinforcement fibers. H-22 wheels to be used with a 1000 gram load on each wheel. COLD RESISTANCE 1. Hose shall have a capability of use down to -35 degrees P, Hose shall have no apparent damage to cover, jacket or lining when subjected to the following cold bending test: A 50 foot length of dry hose is to be firmly coiled and placed in a cold box at -35 degrees F. for a duration of 24 hours. Immediately after the removal of the hose from the hose from the box, the hose should be uncoiled and laided out by one operr.tor. Following this prooedure, the hose shall not leak nor show any damage to any thread In the jacket when subjected to hydrostatic acceptance test requirements listed below. ACCEPTANCE MINIMUM BURST MINIMUM KINX DIAN= PRESSVRZ PRESSURE PRESSURE 5 inch 300 p08.1. 500 P.B.I. 200 p.s.i. 2. Each section of hose is to be tested with the couplings which are to be supplied with the hose at acceptance pressure in- dicated above. 3. Certification of such testing is to be provided. 4. Hose shall be capable of withstanding an Annual Service Test Pressure of 250 p.s.i, for a period of five (5) minutes. COUPLI 1. Couplings to be Storz quick connect. 2. Coupling components shall be drawn together by not less- than three (3) bolts so designed to prevent damage to the bolt heads when hose is laid, used or loaded. 3. Fire department personnel shall be capable of recoupling hose in the field using only an Allen wrench or disassembly key. In the field is to mean on the street possibly under emergency conditions. 4. At least two lugs per coupling shall have raised indicator marks to insure full positive connection. WEIGHT M CM DIAMETERS: 1. Hose with Storz couplings in 100 foot lengths shall not exceed the following: 5 inch WEIGHT 1101 pounds COLORI Lime yellow for unproved visibility. 2 COL SIZE 30 inches .AT, RJ§ISTANCEs 1. The'�hose when subjected, -to a static pressure •of, 100 p.s.l. shall be capable of withstanding a surface,.temperature :of 1200 degrees P for a minimum of two minutes without bursting.: Heat resistance to be demonstrated on request by the Lodi Fire De. partment. REPAIRABILITY s 1. Cover damage, punctures and other small holes must be able to be: repaired with a vuloanizable patch,.thereby restoring the hose to full operational use. CHEMIC . RESISTAN, Es 1. Exposure and contamination by most chemicals, substances, hydrocarbons, oils, alkalis, acids and greases must have no effect on the short or long term performs .nce of the hose. - 2. Chemical Resistance Chart showing contaminating compounds and solutions, chemical substances, hydrocarbons, oils, alkalis, acids and greases with the period of successful resistance' Is to be submitted with manufactor•s data. MARKINGS: I* Each length of fire'hose shall be indelibly marked in letters and figures at least one (1) inch high with the trade name, name of manufacturer, the month• afA year of manufacture: fc1-t the words "Tested to 300 p.s.i.". 2. Markings shall be in two places on each length of hose, beginning approximately four (4) feet from the ends of the hose. 3. If a manufacturer produces hose at tdore than one factory, each length of hose shall have a distinctive marking to Identify it as the product of a particular factory. 1: The hose shall have an internal diameter of not leas than the trade size of the hose. LENGTH: _ 1. No nominal 50 foot length shall be less than 48 feet. The hose shall be in lengths averaging not less than 50 feet. 3 LF_,NGTHS cont • 2. No nominal 100 foot length shall be less than 98 feet. The hose shall be in lengths averaging not less than 100 feet. 3. The length shall be measured from back to back of'couplings with the hose at a hydrostatic pressure of 10 p.s.i. PUNCTURE F,XPANSIO : 1. Hose stall be capable of supplying continuous. water flow of 1000 rpm with a 3/4 inch out in hose. INSPECTION: 1. Fire hose acquired per these specifications will be tested and inspected for compliance as deemed necessary. If any of the inspected or tested hose fails to comply with the re- quirement of the specifications, the City of Lodi shall have the option of rejecting the entire pruchased lot of the size hose tested. 2. The rejected hose shall be accepted and picked up by the supplier at his sole expense. The City of Lodi shall not be liable for the purchase price or for any costs or expense of shipment In connection with the rejected fire hose. 3. In such event, the City of Lodi shall have the right to terminate the contract. WARRANTY: 1. The manufacturer of the hose offered under these specifloations shall warranty the hose against failure from faulty materials or workmanship for a period of ten (10) years. 2. The warranty shall carry the express condition that any hose removed from service during this period of ten years because of defects in materials or workmanship, including pin holing or cracking shall be replaced free of charge (including freight costs) with a like amount of hose that meets these specifi- cations. 3. If the bidder is not a manufacturer, he will have the warranty issued by the manufacturer of the hose furnished. Purported warranties by a distributor is not acceptable. SAMPLES: 1. A full 100 foot length of proposed hose bid, complete with couplings as specified herein, shall be submitted. This sample shall have markings as described above. w. The 100 Toot sample submitted by the successful bidder will be included as partof the shipment and'will be retained by the Lodi Fire Department for use as a control sample to compare with the shipment.,,Any delivered hose that falls to compare in quality, appearance or workmanship with the control sample x111 be rejected. 5. Samples of hose submitted by unsuccessful bidders will be re- turned at City expense. 6. Hose samples must be delivered to: Lodi Fire Department 210 West E1m.Street Lodi, Ca. 95240 DELIVERY: • 1. Bidders shall specify in their bids the earliest date on which delivery x111 be made. 2. All bids are to be on the basis of F.O.B. Lodi, California 3. Delivery of hose shall be made to Lodi Fire Department 705 East Lodi Ave. Lodi Ca. 95240 (209; 333-6735 MANUFACTURER'S DATA 1. The bidder is required to submit with his bid, complete specification sheets describing but not limited to the followings a. Hose construction b. Accelerated Aging Test _ a. Abrasion resistance test without exposure of synthetic reinforcement fibers. S MANUFACTURER'S DATA cont ._ d. Abrasion resistance teat without damage to the synthetic reinforcement fibers. e. Cold Resistance f. Ozone Resistance g. Hydrostatic Pressure Test h. Weight and, Coi1;,Diameters 1, Heat Resistance J. Statement of Repairability k. Service locations for repair 1. Chemical Resistance -Chart m. Friction loss characteristics (P.S.I. PER 100 for the following gpm flows: ?50 gPm 1000 gpm ' 1250 gpm 1500 gpm G