HomeMy WebLinkAboutAgenda Report - January 19, 2011 C-08AGENDA ITEM Cow
CITY OF LODI
COUNCIL COMMUNICATION
AGENDA TITLE: Adopt Resolution Authorizing the City Managerto Enter into a Six Month
Professional Services Agreement with Strategic Power Placements of Conifer, CO
for Electric Superintendent Services and Administration by the Electric Utility
Director ($67,500)
MEETING DATE: January 19,2010
PREPARED BY: Electric Utility Director
RECOMMENDED ACTION: Adopt a resolution authorizing the City Manager to enter into a six
month Professional Services Agreement with Strategic Power
Placements of Conifer, CO for Electric Superintendent Services,
and administration by the Electric Utility Director in an amount not to
exceed $67,500.
BACKGROUND INFORMATION: The City Council approved a superintendent position in the
FY2010/11 Electric Utility Department (EUD) budget. To date EUD
has been unsuccessful in filling this position.
Staff has contacted various electric utility agencies to find a qualified candidate. The American Public
Power Association was successful in recommending an individual qualified to perform Electric
Superintendent duties through Mycoff, Fry and Prouse Management Services, LLC doing business as
Strategic Power Placements (SPP) in Conifer, Colorado.
Staff recommends the City Council adopt a resolution authorizing the City Manager to approve the
attached Professional Services Agreement with SPP for Electric Superintendent Services with
administration by the Electric Utility Directorfor six months in an amount not to exceed $67,500.
FISCAL IMPACT: No additional funding is required.
FUNDING AVAILABLE: Included in FY2010/11 EUD Budget Account No. 160650.7323.
Jordan Ayers
Deputy City Manager/Internal Services Director
Eli beth A. Kirkley
E ectric Utility Director
APPROVED:
onradt Bartlam, City Manager
PROFESSIONAL SERVICES AGREEMENT
BETWEEN
CITY OF LODI
AND
MYCOFF, FRY & PROUSE MANAGEMENT SERVICES, LLC
This PROFESSIONAL SERVICES AGREEMENT ("`Agreement" )ofJanuary 24,201 I between Lodi
Electric Utility located at Lodi, California and Mycoff, Fry & Prouse Management Services, LLC doing
business as Strategic Power Placements (SPP) with offices at 12935US Highway 285, Conifer, CO 80433
WHEREAS Lodi Electric Utility is engaged in the generation, transmission, and/or distribution of electrical
energy; and
WHEREEAS, SPP is qualified and capable of providing interim management consulting services;
NOW, THEREFORE, in consideration of the promises herein and for other good and valuable
consideration, the parties agree as follows:
1. Services to be provided Lodi Electric Utility engages SPP to provide interim management consulting
services and other services (hereinafter referred to as the "Services") as described in Exhibit A. Detailed
procedures and practices to be followed while performing the Services, including completion acceptance,
shall be as set forth in a project specific task order issued thereunder. SPP will perform the Services at the
direction of and on behalf of Lodi Electric Utility.
2. Independent Contractor: SPP is an independent contractor and is not an employee of Lodi Electric Utility
and shall not be entitled to any benefits or rights, including, but not limited to, sick leave, vacation leave,
holiday pay, worker's compensation or other insurance benefits.
Standard of Care: SPP will perform Services under this Agreement with the degree of skill and diligence
normally practiced in the energy industry. SPP shall comply with all Federal, State, County, City and other
governing laws, rules and regulations as applicable to the performance of services under this Agreement
including Lodi Electric Utility business practices or other ordinances including, but not limited to, equal
opportunity practices, living wage ordinances, applicable business licenses, taxpayer protection acts (limiting
gifts or campaign contributions), and assignment of antitrust causes of action.
4. Payment: Lodi Electric Utility agrees to pay SPP for services in accordance with the terms and schedule
contained in Exhibit B. Each invoice shall state the basis for the amount invoiced, including services
completed, units and costs, and any work performed. Lodi Electric Utility shall pay properly invoiced
amounts not more than sixty (30) days after delivery of an invoice.
Changes/Amendments: This Agreement may not be changed except by written amendment signed by both
Parties. Services not expressly set forth in Exhibit A are excluded. SPP shall promptly notify Lodl Electric
Utility if changes to the Services affect the schedule, level of effort or payment to SPP. If SPP determines that
changes should be made to Exhibit A or Exhibit B, SPP will notify Lodi Electric Utility of such proposed
changes in writing, including the effects on the schedule, level of effort and payment for such changes.
Thereafter, SPP and Lodi Electric Utility shall agree in writing on which changes, if any, shall be included in
an amendment to either Exhibit A or Exhibit B. If SPP is delayed in performing the Services by any act of
war, force majeure or other circumstancebeyond its control, SPP shall not be considered to be in default of
the performance of its obligations under this agreement.
6. Taxes: Any and all taxes imposed on SPP's income, imposed or assessed by reason of this agreement or its
performance, includmg but not limited to sales or use taxes, shall be paid by SPP. SPP shall be responsible for
any taxes or penalties assessed by reason of any claims that SPP is an employee of Lodi Electric Utility, and
Lodi Electric Utility and SPP specifically agree that SPP is not an employee or agent of Lodi Electric Utility.
Indemnity: To the extent permitted by law, SPP agrees to indemnify, defend and hold harmless Lodi Electric
Utility directors, officers and employees from and against any and all loss, damage, claims or liability,
includmg reasonable attorney's fees incurred by Lodi Electric Utility in connection with the provision of the
Services to the extent arising out of SPP's negligence, wi l l fi i misconduct or bad faith. T o the extent permitted
by law, Lodi Electric Utility agrees to indemnify, defend and hold harmless SPP its directors, officers and
employees from and against any and all loss, damage, claims or liability, includmg reasonable attorney's fees
incurred by SPP in connection with the provision of this Services to the extent arising out of Lodi Electric
Utility negligence, willful misconduct or bad faith.
8. Limitation of Liability: To the extent permitted by law, the total liabdity of SPP to Lodi Electric Utility for
any claims arising out of this Agreement, whether caused by negligence errors, omissions, strict liability,
breach of contract or contribution, or indemnity claims based on third party claims, shall be limited to direct
damages and shall not exceed one hundred and fifty thousand dollars ($150,000) or the insurance limits
required in Paragraph 9, whichever is greater; provided, however this limitation shall not apply to claims
arising from or out of the gross negligence, willful misconduct or bad faith of SPP.
IN N O EVENT AND UNDER N O CIRCUMSTANCES SHALL SPP BE LIABLE TO LODI
ELECTRIC UTILITY FOR ANY INTEREST, LOSS OF ANTICIPATED REVENUES, EARNINGS,
PROFITS, INCREASED EXPENSES OF OPERATIONS, LOSS BY REASON OF SHUTDOWN OR
NON -OPERATIONS DUE TO LATE COMPLETION OR FOR ANY CONSEQUENTIAL,
PUNITIVE, INDIRECT OR SPECIAL DAMAGES.
Notwithstanding the forgoing, this damages waiver shall not apply to damages for payments made by Lodi
Electric Utility to SPP under this Agreement and nothing in this Agreement shall preclude Lodi Electric
Utility from recovering such payments in the event SPP fails to perform the Services provided for under the
Agreement.
The warranties, obligations, liabihties and remedies of the parties, as provided herein, are exclusive and in lieu
of any others available at law or in equity. To the fullest extent allowed by law, releases from, and limitations
of, liability shall apply notwithstanding the breach of contract, tort including negligence, strict liabdity or other
theory of legal liabdity of the party released or whose liabihty is limited.
9. Insurance: SPP shall, at its own cost and expense, procure and maintain during the entire term of this
Agreement, public liabihty insurance and property damage insurance (issued by an insurance company
admitted in the State of California to issue such insurance) naming Lodi Electric Utility as an additional
insured against loss or liabdity caused by or connected with SPP's use of an automobile in the performance of
this Agreement. The policy shall meet the insurance requirements for the City of Lodi attached as Exhibit C
and incorporated herein.
Additionally, SPP shall, at its own cost and expense, secure and maintain during the entire term of this
Agreement, a policy of workers' compensation insurance with statutory limits or provide a waiver certifying
that no employees and/or volunteers subject to the Labor Code provisions will be used in the performance
of services under this Agreement.
This insurance shall not be cancelled, limited in scope or coverage or non -renewed until after thirty (30) days
written notice has been given to Loch Electric Utility.
10. Term and Termination: The term of this Agreement shall be one year from the date of execution, at which
time, it shall either terminate or be extended by written agreement between Lodi Electric Utility and SPP,
unless sooner terminated in accordance with this section. Either Party may terminate this Agreement, without
cause, upon thirty (30) days' written notice to the other Party. Lodi Electric Utility shall pay SPP for all
services rendered to the date of termination plus reasonable expenses for winding down the services. Any
payment, indemnity, and work product rights or obligations, shall survive the termination of this Agreement.
11. Use and Ownership of Work Products:
(a) Work Product. As used in this Agreement, the term "Work Product" means any and all materials fixed in a
tangible medium of expression, including software code, written procedures, written documents, abstracts
and summaries thereof, or any portions or components of the foregoing created, written, developed,
conceived, perfected or designed in connections with the Services provided under this Agreement.
(b) Loch Electric Utility shall retain all rights, title and interest in and to the Work Product, including all
intellectual property rights therein and any and all enhancements, improvements and derivative works thereof,
and SPP obtains no right therein.
(c) At all times, each party shall retain all of its rights in its drawing details, designs, specifications, databases,
software, programs, copyrights, trade and service marks, patents, trade secrets, and any other proprietary
property.
12. Information Provided by Others: Lodi Electric Utility shall provide to SPP in a timely manner any
information needed to perform the services hereunder. SPP may rely on the accuracy of the information
provided by Lodi Electric Utility and its representatives.
13. Dispute Resolution: SPP and Lodi Electric Utility shall attempt to resolve conflicts or disputes under this
Agreement in a fair and reasonable manner and agree that if resolution cannot be made, to mediate the
conflict with a professional mediator. If mediation does not settle any dispute or action which arises under
this Agreement or which relates in any way to this Agreement or the subject matter of this Agreement, it shall
be subject to arbitration under rules governing commercial arbitration as promulgated by the American
Arbitration Association, arbitrability shall be subject to the Federal Arbitration Act and the locale of the
arbitration shall be California.
14. Miscellaneous:
(a) This Agreement is binding upon and will inure to the benefit of the Lodi Electric Utility and SPP and their
respective successors and assigns. Neither party may assign its rights or obligations hereunder without the
prior written consent of the other Party; provided, however, that either Party may assign this Agreement to a
successor of the Party's entire business relating to this Agreement.
(b) If any term or provision of this Agreement is illegal, invalid, or unenforceable under any present or future
law, then, in such event, it is the intention of the parties hereto that the remainder of this Agreement shall not
be affected thereby, and it is also the intention of the parties to this Agreement that in lieu of each term or
provision of this Agreement that is illegal, invalid or unenforceable, there will be added, as apart of this
Agreement, a legal, valid and enforceable term or provision as similar in content as possible to such illegal,
invalid or unenforceable term. If any provision in the body of this Agreement conflicts with any provision in
any exhibit or attachment hereto, the provision contained in the body of the Agreement shall control over
any such other conflictingprovision.
(c) This Agreement is entered into in California and shall be governed by, and construed in accordance with, the
laws of the State of California.
15. Signature Clause:
IN WITNESS WHEREOF, each signatory hereto represents that he or she has been properly authorized to
execute and deliver this Agreement on behalf of the Parry for which he or she signs.
Lodi Electric Utility
and;
Strategic Power Placements
10
Carl A. Mycoff
Manager
Strategic Power Placements LLC
12935 US Highway 285
Conifer, CO 80433
(800) 525 9082
Exhibit A
SCOPE OF SERVICES
Between
Lodi Electric Utility
and
StrategicPower Placements ("SPP")
Pursuant to the terms and conditions of the Professional Services Agreement ("Agreement") executed and
made effective as ofJanuary 24,2011 by and between Lodi Electric Utility and SPP, SPP will provide Maury
J. Blalock for Interim Electric Superintendent Services to Lodi Electric Utility from January 24,2011 until
July 24,2011 to work under the direction of Lodi Electric Utility.
OVERVIEW
Under general direction, assigns and supervises the activities of the electric systems for Lodi's Electric Utility
Department. Performs a variety of professional office and field work relating to construction and
maintenance of electric utility systems, substations, communication network, metering and control systems.
Provides administrative direction and technical assistance and training to division staff, and does related work
as required.
JOWLEDGE OF
Methods, materials, and tools used in construction, maintenance and repair of power substations,
transformers, circuit breakers, surge arresters, battery systems, capacitor banks & associated controls,
generator & appurtenances, protective relays and devices, SCADA systems, motor controllers, process
control and instrumentation devices, metering, security& alarm systems and solid state and micro -processor
systems;
Detailed analysis of power outages and protective device indications;
Instrumentation, specialized testing equipment and precision tools;
Power equipment diagnostic testing and interpretation of test results;
Effective grounding system, ground potential rise, synchronizing systems, load shedding & reclosing control
systems, phase shifters, different HV/MV bus configurations, parallel system operations, power quality
analysis, instrument transformers, three-phase & single-phasepower systems;
Electrical and environmental codes, laws, and safety rules associated with power substation and other high
and medium voltage work;
Reliability standards applicable to electric utility systems;
Principles of supervision, training, and performance evaluation;
Safe work practices and procedures;
Record keeping and reporting procedures.
A-7
ABILITY TO
Plan, organize and supervise the day-to-day activities of the Substation Maintenance Section and the Metering
Section;
Work independently;
Supervise, train and evaluate subordinates;
Maintain work and operationalrecords and prepare technical reports;
Use tools, equipment, and software employed in the course of work in the Substations and the office;
Prepare clear, concise and complete technical documents, reports and correspondence;
Communicate clearly and concisely.
Work safely in a 60kV environment;
Participate with various City departments and outside agencies in the planning and design of electric facilities;
Establish and maintain effectiveworking relationships with those contacted in the course of work.
GUISHIT ;H ARACTER [S'
This is a supervisory level position directly responsible for the activities of the Substation Maintenance
Section and the Metering Section. The Electric Superintendent is distinguished from the Electrical
Technician and the Metering Technician and Electricians in that the incumbent must possess a thorough
technical and working knowledge of power substations, electric systems, protection systems, reliability
compliance, communications, metering and control systems, their components, devices and functions
including computer and computer-based SCADA, digital fault recorder, modem, telemetry, intelligent
electronic devices (IED), fiber optics, remote terminal units, programmable logic controllers, multiplexers,
digital substation technology, microprocessor -based test and process control equipment, system hardware,
software and network components, network protocols and integration, single-phase and multi -phase
configuration.
SUPERVISION RECEIVED AND EXERCISED
Receives general direction from the Assistant Electric Utility Director or designee. Supervises Electrical
Technician, Metering Electrician and others as assigned.
EXAMPLES OF DUTIES
Duties may include, but are not limited to, the following:
Coordinates assignments with Electric Utility Department and other Departments' staff,
Directs, trains, evaluates, and, coordinates in the construction, maintenance, troubleshooting, repair and
operation of power substations and meters;
Performs pre- and post -inspections of electrical construction and maintenance tasks;
A-2
Specifies special materials and equipment needed for all phases of substation and metering work within the
city;
Reviews and comments on plans and specifications submitted by contractors and consultant engineer;
Participates in the design of electrical systems for power substations and municipal facilities;
Develops and maintains preventive maintenance programs and records;
Implements the hazardous materials handling, recordkeeping and coordination internally and with governing
agencies;
Directs, trains, and evaluates technical staff in the maintenance, calibration, troubleshooting, and repair of
power substation equipment, municipal electric facilities, SCADA systems, process control and
instrumentation devices, metering and other computer and electronic -based systems;
Recommends & implements safety procedures, training and guidelines; acquires necessary protective gear,
tools and devices to enhance personnel and equipment safety;
Interacts with customers when solving power quality and metering problems;
Participates in budget preparation; implements the Division's policies, procedures, and practices;
Performs the duties of Electrical Technician, as needed;
Performs other duties related to the safe, reliable operation of the department and the City including
additional duties that enable the department and City to meet the diverse needs of its community.
A-3
Exhibit B
COMPENSATION
For the first six months of this Agreement, Maury J. Blalock will perform work under this Agreement at a
monthly rate of $11,250, which includes all SPP costs, as well as, travel and per diem expenses. After July 24,
2011 Lodi Electric Utility can elect to enter into an amendment for another interim placement should Lodi
Electric Utility determine it has additional personnel needs. In such an event, SPP wi work to identify
qualified interim candidates; any professional fees to be charged for additional interim placements wi be
negotiated.
Exhibit C
Insurance Reauirements for Consultant The Consultant shall take out and maintain during the life of this contract, insurance
coverage as listed below. These insurance policies shall protect the Consultant and any subcontractor performing work covered by
this contract from claims for damages for personal injury, including accidental death, as well as from claims for property damages,
which may arise from Consultant's operations under this contract, whether such operations be by Consultant or by any subcontractor
or by anyone directly or indirectly employed by either of them, and the amount of such insurance shall be as follows:
COMPREHENSIVE GENERAL LIABILITY
$2,000,000 Ea. Occurrence
$4,000,000 Aggregate
2. COMPREHENSIVE AUTOMOBILE LIABILITY
Proof of coverage with limits not less than $1,000,000 combined single limit and naming the CITY, by separate endorsement,
as an additional insured.
PROFESSIONAL ERRORS AND OMISSIONS
Not less than $1,000,000 per Claim. Certificate of Insurance only required.
NOTE Contractor agrees and stipulates that any insurance coverage provided to the City of Lodi shall provide for a claims period
following termination of coverage which is at least consistent with the claims period or statutes of limitations found in the California
Tort Claims Act (California Government Code Section 810 et seq.).
A copy of the certificate of insurance with the following endorsements shall be furnished to the City:
(a) Additional Named Insured Endorsement
Such insurance as is afforded by this policy shall also apply to the City of Lodi, its elected and appointed Boards, Commissions,
Officers, Agents, Employees, and Volunteers as additional named insureds.
(This endorsement shall be on a form furnished to the City and shall be included with Contractor's policies.)
(b) Primary Insurance Endorsement
Such insurance as is afforded by the endorsement for the Additional Insureds shall apply as primary insurance. Any other
insurance maintained by the City of Lodi or its officers and employees shall be excess only and not contributing with the
insurance afforded by this endorsement.
(c) Severability of Interest Clause
The term "insured" is used severally and not collectively,but the inclusion herein of more than one insured shall not operate to
increase the limit of the company's liability.
(d) Notice of Cancellation or Change in Coverage Endorsement
This policy may not be canceled nor the coverage reduced by the company without 30 days' prior written notice of such
cancellation or reduction in coverage to the Risk Manager, City of Lodi, 221 W. Pine St., Lodi, CA 95240.
Compensation Insurance The Contractor shall take out and maintain during the life of this contract, Worker's Compensation
Insurance for all of Contractor's employees employed at the site of the project and, if any work is sublet, Contractor shall require the
subcontractor similarly to provide Worker's Compensation Insurance for all of the latter's employees unless such employees are
covered by the protection afforded by the Contractor. In case any class of employees engaged in hazardous work under this contract
at the site of the project is not protected under the Worker's Compensation Statute, the Contractor shall provide and shall cause each
subcontractor to provide insurance for the protection of said employees. This policy may not be canceled nor the coverage reduced
by the company without 30 days' prior written notice of such cancellation or reduction in coverage to the Risk Manager, City of Lodi,
221 W. Pine St., Lodi, CA 95240.
C-1
RESOLUTION NO. 2011-11
A RESOLUTION OF THE LODI CITY COUNCIL AUTHORIZING
THE CITY MANAGER TO ENTER INTO SIX-MONTH
PROFESSIONAL SERVICES AGREEMENT WITH STRATEGIC
POWER PLACEMENTS, OF CONIFER, CO, FOR ELECTRIC
SUPERINTENDENT SERVICES AND ADMINISTRATION BY
THE ELECTRIC UTILITY DIRECTOR
--irv---. -.-&-.r:::::::: ------.-.-.- : ::::::::--------.-. -.- :::::: � : - . TTTr, ---
WHEREAS, the City Council approved a superintendent position in the Fiscal Year
2010/11 Electric Utility Department (EUD) budget; and
WHEREAS, to date, EUD has been unsuccessful in filling this position; and
WHEREAS, staff has contacted various electric utility agencies to find a qualified
candidate; and
WHEREAS, the American Public Power Association was successful in recommending
an individual qualified to perform Electric Superintendent duties through Mycoff, Fry and Prouse
Management Services, LLC doing business as Strategic Power Placements (SPP) in Conifer,
CO.
NOW, THEREFORE, BE IT RESOLVED that the Lodi City Council does hereby
authorize the City Manager to enter into a six-month Professional Services Agreement with
Strategic Power Placements, of Conifer, CO, for Electric Superintendent Services and
administration by the Electric Utility Director in an amount not to exceed $67,500.
Dated: January 19, 2011
hereby certify that Resolution No. 2011-11 was passed and adopted by the City
Council of the City of Lodi in a regular meeting held January 19, 2011, by the following Vote:
AYES: COUNCIL MEMBERS - Hansen, Katzakian, Mounce, and
Mayor Johnson
NOES: COUNCIL MEMBERS- None
ABSENT: COUNCIL MEMBERS- Nakanishi
ABSTAIN: COUNCIL MEMBERS -Non
OHL
City Clerk
2011-11
C Sc
RESUME OF
MAURY J. BLALOCK
QUALIFICATIONS
Over 40 years of broad based Electrical Engineering and Management experience with
demonstrated achievements in project engineering, construction, and management as well as
organization development and management, strategic planning, and financial analysis. A
Registered Professional Engineer in the State of Florida.
WORK HISTORY
1987 - Present
BLALOCK AND ASSOCIATES, INC.
President and founder of Blalock and Associates, Inc., an engineering consulting business
incorporated in the State of Florida - 1988.
Successfully managed and expanded an engineering consulting business
engaging in applied electrical engineering consulting; heat loss and/or
energy studies; utility rate studies and consultation; utility (gas and
electric) avoided cost and marginal cost studies and analyses; utility (gas
and electric) cost of service and load forecast studies and analyses; utility
(gas and electric) conservation and DSM (Demand Side Management)
program development; electric service quality studies and analyses;
organization studies and analyses associated with public and private
businesses; installation and operation of electrical/mechanical systems for
residential, commercial, and industrial establishments;AM/FM/GIS
development and implementation; FERC/NERC/ERCOT Transmission
System Operator compliance evaluation/documentation/program
development; and, providing management and financial advice and
consultation, project financing and development, and computer
hardware/software systems and services.
1966- 1987
TAMPA ELECTRIC COMPANY
Manager, Conservation and Load Management.
Successfullymanaged the engineering, vender selection, system
implementation, and field installation of all conservation and load
management related equipment.
Maury I Blalock Resume
Page 2
Developed all Direct Load Control Programs and all the related Public Service
Commission filings including cost-effectiveness studies from the inception of
these programs in 1980 through their maturity in 1987. By the end of 1987,
50,000 customers were under direct control either through VHF radio or bi-
directional powerline carrier.
Developed a Direct Load Control Manual which encompassed all aspects
of the programs including construction standards, engineering standards,
customer solicitation, departmental integration, cost accounting, control
system configuration and testing, control strategy development and
implementation, etc.
Directed all marketing efforts associated with the Direct Load Control
Programs.
Successfully managed the integration of the Load Control System (VHF
radio and Bi-directional PLC) into the Tampa Electric Company SCADA
and System Generation and Transmission Dispatch Operations.
Aided in the development of all Energy Conservation Programs from their
inception in 1980 through their maturity in 1985.
Senior Engineer, System DistributionEngineering Design and Planning
Successfully staffed and managed a new corporate level engineering
department with responsibility for distribution system expansion planning,
distribution construction design standards, and distribution equipment
purchasing specifications.
Developed a Transformer Load Management System encompassing all
80,000 distribution transformers and all 400,000 customers.
Developed a Small Area Load Forecasting System and integrated it with
the Transformer Load Management System and they became the primary
Distribution System Planning Tools.
Developed a Distribution Work Order Automation System which used
units of property (distribution system components) and labor units
(personnel) to generate construction work orders and capital expansion
cost estimates from Distribution construction Design Standards.
Maury I Blalock Resume
Page 3
Developed a complete Distribution Construction Design Standards Book
encompassing both URD and Overhead construction, and developed a
Distribution Engineering Manual which encompassed all aspects of system design
including fuse coordination, power factor correction, transformer configurations,
conductor sizing, etc.
Division Engineer, Polk County Division
Management and budgetary responsibilities for the Field Distribution
Engineering Section, Division Distribution Dispatch Center, Division
Metering Section, and Division Storeroom.
Developed training courses in Distribution System Dispatching and
Clearance Techniques, Distribution Substation Switching Procedures,
Distribution System Protection Coordination (fuse and relaying), and
Distribution Safety Procedures.
Senior Engineer, System Generation and Transmission Planning
Direct responsibility for the 20 -year System Generation Expansion Plan
encompassing three generating plants and 3000 MW of generation
capacity.
Direct responsibility for the 20 -year System Transmission and Substation
Expansion Plan encompassing fifty 69 KV circuits, six 138 KV circuits,
twelve 230 KV circuits and eighteen transmission substations.
Developed a computerized Transmission System Load Flow Program
which became the primary planning and operating tool for the company.
Developed a DistributionNetwork Load Flow Program which became the
primary planning and operating tool for the downtown network system.
Engineer, Substation Operation Department
Direct responsibility for the panel wiring and installation and checkout of
all relaying and controls in all distribution and transmission substations
during six years of the fastest expansion of these facilities in company
history.
Maury J. Blalock Resume
Page 4
Designed and supervised construction of a vacuum drying system for
substation transformer cores and switchgear.
Developed checkout equipment and procedures to facilitate fast and
accurate checkout of all substation relaying and controls.
Developed test equipment for testing overcurrent relays, differential
current relays, distance relays and transfer trip relaying.
EDUCATION
BACHELOR OF SCIENCE - ELECTRICAL ENGINEERING, University of Florida - 1966.
REGISTERED ELECTRICAL ENGINEER, State of Florida - 1972.
Graduate of the General Electric Protective Relay Course.
Graduate of the Public Utility Executive Course, Georgia Tech .
SERVICE
Served on the Transmission and Generation Planning Committee of the
Edison Electric Institute.
Served on the Overhead and Underground Distribution Committee of the
Southeastern Electric Exchange.
Served on the Load Management Committee (first Committee Chairman —
1982) of the Florida Utilities Coordinating Group.
Served as an Industry Advisor on three major EPRI projects.
The Institute of Electrical and Electronics Engineers — IEEE
Past member of the Florida Coordinating Group — FCG