Loading...
HomeMy WebLinkAboutAgenda Report - January 15, 1992 (60)OCIN OF LODI - couNcrL COMMUNICATION AGENDA TITLE: Specifications and Advertisement for Bids for Polemount Transformers MEETING DATE: January 15, 1992 PREPARED BY: Electric Utility Director YDED ACTION: That the City Council approve the specifications and authorize advertisement for bids for the purchase of 9 circuit -protected and 45 conventional polemount transformers of various ratings. BACKGROUND INFORMATION: The transformers w i I I be installed as replace- ments for PCB -contaminated units. and to replenish the Department's inventory. The bid opening has been scheduled for Tuesday. February 18. 1992. FUNDING: The estimated cost of this purchase is $45.000. with funding available in the Electric Utility Department's Operating Fund. W L - I Henry J. Rice, Electric Utility Director cc: Assistant Electric Utility Director Electrical Engineer APPROVED THOMAS A PETERSON City Mannger J cc T SPECIFICATIONS POLEMOUNTED TRANSFORMERS - OIL FILLED DIVISION 1- GENERAL PECUI REMENT5 1-1 GENERAL Electrical design and materials shall conform to the latest E£1 -HEMA and AMS1 Standards. It i s the intent of these specifications to describe ecuipmer.t of the best design and construction, for the service for which it i s intended. Consequently, i t shall be the City's desire to award contracts to the bidder who has demonstrated high quality by having a considerable number of transformers of his manufacture ir service on the lines of electrical utilities over a period of years. 1-9 TTgTC Transformers shall receive at least the followina tests in accordance wirh the applicable AI'dSI and NEHA Standards: ( 1 ) Load and no-load loss (2) Exciting current (3) Polarity check (4) Ratio check 1-3 SERVICE (5) Applied and induced potential test (6) impulse voltage test (7) Tank pressure test The manufacturer shall own and operate a service shop in this vicinity, or the bidder may submit evidence that he has a repair contract with an approved service shop in this vicinity, which has been in effect ror a period of at least one year. (For the purpose of this specification: Vicinity shall mean within a 200 -mile raaius of the city of Lodi). 1-4 GUARANTEE The manufacturer srall guarantee all equipment delivered under these specifications against any and all defects in material and/or workmanship for a period of at least one year frog: date of acceptance. He shall rectify all such defects by repair or replacement at his own expense and assume responsibility for associated shippino cos';. S-11 S-EUD91.5iIX U.91D 06/19/91 POLEMOUNT TRANSFORMERS - NL -FILLED Oivi;on 1 - General ReouirementS (continued) 1-5 TECHNICAL INFORMATION The *ollow inq specifications shall be met: 1, Insulation level: 95 0 BIL (min.). 2. l p a- -4tr i con rating: 65°C rise. 3. Paint: All exterior surfaces shall be painted ANSI 70 gray. using a system of coordinated and thor-unhly tested materials and application techniques that will assure long life. Special attention shall be given to welds, se,3ns, edges and rouch spots. 4. Lif=ino lues: Lifting lugs shall be provided on the tank and shall be located in such a way to avoid inte<erencP between liftir.j slings and any attl;hmPnts on the transformer and to a,J.oia scratching the transformer coating. 5• Tank- Tanks shall be testec at a pressure equal to or greater than the maximum operatinq pressure and for a sufficient period of tine to insure that all welds are free from leaks. Tank construction shall be consistent with Good manufacturing and design practices prevalent in the transformer industry, and toaether they should contribute to a high quality product. 5. Name Ute: Stainless steAl or anodized aluminum nameplate shall be s,,rely attached to the transfor-er by means of metal screws. rivets or similar mechanical devir_e(s), The letters and numbers shall be stamped or enoraved on the nameplate. The nameplate steal; include the words, "Fluid is less than one p,p.m, PCB," refer to Section 1-i, The instruction nameplate shall contain the inform- ticn specified in Section 5.12 of ANSt Standard C57.12.00 - 1980. 7. Sound Level: The sound level shall be equal to or better than EE i -+'NEMA Standards. S. Size: Size of the transformer, includinn radiators (fins), shall nor_ interfere with installation or G.O. 95 reouirements when banked toqether on cluster bracket (Dixie Electric P-538 or approved equal'. 9. Hesaht 8 weight: listed bz pT w: Size (KVA) ,:5 37.5 50 75 100 167 Height and weight of Lhe transformer 5ha11 be as Maximum Weicht (',bs.) 500 625 800 1,100 1,200 1,600 M3A imum Heioht (inches) ncludino Bush inos 45 45 45 45 51 51 51 5-7 S-EUD91.5/TXTU.01D 06119/91 POLEMOUNT TRANSFORMERS - OIL -FILLED Division I - General Reouirements (continued) 1-6 LOSSES Losses will be considered in the evaluation of this bid as foilows: No-load (core) loss 0 56.00/watt. Load (winding) loss @ S2,00/watt The cost of losses will be added to the equipment price !bid price) F,O,$, Lodi , i nc i ud i ng maximum escalation, to de tern i rie the evaluated low bid of vendor otherwise meeting these specifications. AEI bidders shall supply the fol€Owing guaranteed loss data for use in the evaluation, in addition to other data listed in the s pec i f i ca t i ens : 1. No-load losses in watts at rated secondary voltage. 2. Load losses in watts at rated secondary voltage ana rated load, The standard reference �emoeraure for 'toad losses shah be 851C. a, Upon request. furnish of the Guaranteed loss measurement error of the test equipment and measurement method to be used, including the basis for determination of the accuracy of the test eouipment and measurement method, The successful bidder shall supply a certified test report of actual losses of :he unit(s) to be supplied. The no-load and load losses for each group (type and size) of transformer(s) will be averaged separately within their respective categories (no-load and load losses). , If the averaged tested no-load (core) and/or load (windin,j) losses of the transforr..er group exceed the watt losses quoted in the prcposal, the contract price shall be reduced by the above 'amunts per watt of actual gr(-uo averaged no-load and/or actual load loss in excess of that quoted in the proposal. ;io-load loss on- )lties will be evaluated separately from load 1—s non,'"es. IN additional payment will be made to the manufacture- C. actual losses lower than the losses Quoted in the proposal. Certified test report of losses shall be submitted by the manufacturer prior to or at the time of shipment of the transformer. 1-7 PCB CONTENT Transformer fluid shall be Guaranteed to contain less than one Q,p,m, by weight (no/ kg) polychlorinated biphenyls (PCS), Certified test report of PCS content shall ee produced upon request, The transformer nameplate to include the words, "Fluid is less Than one p.p.m. PCP," S-EUD91.5/TXTU.01D 06/19/91 POLEMOUNT TRANSFORMERS • 0[l.-FlU E0 DIVISION 2- SINGLE-PHASE 2-1 GENERAL In addition to that specified in Divisicn 1 - General Requirements, transformers shall be provided with the following: 1. High Voltage Bushings (Porcelain): a. Quantity: Two b. Bushing terminals to be clamp -type suitable for use with copper and aluminum conductor. 2. Low Voltage Bushings (Porcelain): a. Quantity: 217 -volt; Two All Others: Three b. Shall be tank wall -mounted. C. Bushing terminals: 100 K"'A and lower: Shall be clamp -type suitable for use with copper and aluminum conductor. Over 100 KVA; Shai 3 be NEW -4 pads (4 -hole) . 3. Pressure relief valve: Qua litro1 202-030-01, or an ar.^roved equal. 4. Lifting luas shall be welded to the tank. 5. Provide tank grounding pad and a visible tank -to -cover grour;d strap. 6. Hanger brackets, welded to the tank. i. Hanger brackets shall it bolting of transformer directly to pole. g. Single phase, 60 Hz, 01SC, POLEMOUNT€D TRANSFORMERS - OIL -FILLED Division 2 - Single -Phase (continued) 2-2 RATINGS AND DESIGN Transformers shall have the following ratings and design: 1. Distribution type. pole -bolted transformers. 2. 12.000 -vol t Delta primary. 3. Single phase. 1 a. Without arresters and taos. 5. Conventional or CP type as specified on proposal form. CP transformers to have one weak link (fuse) per primary b�5hinc and a breaker on the secondary side. 6. Secondary voltage to be as specified on proposal form. 7. KVA rating to be as specified on proposal form.